Kobold DPL-1E Series Operating Instructions Manual Download Page 8

DPL 

page 8 

 

DPL K07/0322 

8. Commissioning – Evaluating Electronic 

8.1.  Frequency output 

The measuring instruments are preset and after connection ready for operation. 
 
 

8.2.  Analogue output 

The measuring instruments are preset and after connection ready for operation. 
 
 

8.3.  Compact electronics 

The measuring instruments are preset and after connection ready for operation. 
(In  order  to  change  settings  see  the  operating  instructions  for  the  compact 
electronics model ..C30R, ..C30M, ..C34P, ..C34N) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DPL-1E Series

Page 1: ...Operating Instructions for Low Volume Rotating Vane Flow Meter Model DPL 1P DPL 1V DPL 1E...

Page 2: ...able outlet with M12x1 angle plug electronic options F3x and L3x 7 7 6 Compact electronics C30R C30M C34P C34N 7 8 Commissioning Evaluating Electronic 8 8 1 Frequency output 8 8 2 Analogue output 8 8...

Page 3: ...with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit should be used only when the...

Page 4: ...rical output is available as an option The frequency is proportional to the flow velocity The vane has a sapphire bearing and ensures a high degree of linearity and long service life 6 Mechanical Conn...

Page 5: ...the unit s electronics 7 2 DPL 0000 frequency output OEM without cable Feed voltage receiver 4 5 16 VDC Feed current receiver typ 7 mA Signal amplitude High approx operating voltage Signal amplitude L...

Page 6: ...ectronic Frequency output Plug connection M12x1 F3 Cable connection F5 7 4 Evaluating electronic Analogue output L 3 wire connector M12x1 3 wire DIN plug 43650 DPL L303 L343 DPL L403 L443 1 2 3 4 Vs S...

Page 7: ...L3x When using a pre assembled M12x1 connection cable with angled plug the cable outlet is always aligned opposite to the flow direction 7 6 Compact electronics C30R C30M C34P C34N See Operating Instr...

Page 8: ...ion ready for operation 8 2 Analogue output The measuring instruments are preset and after connection ready for operation 8 3 Compact electronics The measuring instruments are preset and after connect...

Page 9: ...tic filter model MFR If cleaning of the sensor is necessary the sensor can be opened so that the inner parts are accessible Take care that the sensor and especially the vane are not damaged make sure...

Page 10: ...er supply 4 5 12 VDC Supply current approx 7 mA Signal amplitude high approx power supply Signal amplitude low 0 2 V Transmitter cut off voltage 3 V max Transmitter supply current 15 mA 25 mA Output l...

Page 11: ...43 650 Option plug on display with plug connector DIN 43 650 and output 4 20mA Compact electronics Display 3 digit LED Analogue output 0 4 20 mA adjustable max 500 Switching outputs 1 2 semiconductor...

Page 12: ...m PVC cable PNP Analogue output L303 0 20 mA output M12x1 plug connector L343 4 20 mA output M12x1 plug connector L403 0 20 mA output plug connector DIN 43 650 L443 4 20 mA output plug connector DIN...

Page 13: ...DPL DPL K07 0322 page 13 12 Dimensions DPL 0000 DPL F3 DPL L3 DPL C3 with compact electronic DPL L4 with analogue output and plug on display...

Page 14: ...ility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General require...

Page 15: ...ents BS EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use General requirements BS EN 60529 1992 A2 2013 Degrees of protection provided by enclosur...

Reviews: