12. Technical Information
Housing
Dimensions
96x24x60 mm (BxHxD)
96x24x74 mm (BxHxD) including plug-in terminal
Panel cut-out
92.0
+0.8
x 22.2
+0.3
mm
Insulation thickness
up to 3 mm
Fixing
snap-in screw element
Material
PC Polycarbonate, black, UL94V-0
Sealing material
EPDM, 65 Shore, black
Protection class
standard IP65 (front), IP00 (back side)
Weight
approx. 100 g
Connection
plug-in terminal; wire cross section up to 2.5 mm
2
Display
Digit height
14 mm
Segment colour
red (optional green, orange or blue)
Display range
-1999 to 9999
Setpoints
optical display flashing
Overflow
horizontal bars at the top
Underflow
horizontal bars at the bottom
Display time
0.1 to 10.0 seconds
Input
Measuring range
Measuring fault
Digit
Pt100 2-/3-wire
-200…850°C
0.1 % of measuring range
±1
Pt100 2-/3-wire
-328…1562°F
0.1 % of measuring range
±1
Accuracy
Temperature drift
100 ppm / K
Measuring time
0.1…10.0 seconds
Measuring principle
U/F-conversion
Resolution
0.1°C or 0.1°F
Power pack
230 VAC ±10 % max. 6 VA
24 VDC ±10 % max. 1 VA
Memory
EEPROM
Data life
≥ 100 years at 25°C