2. Note 

Please read these operating instructions before unpacking and putting the unit 
into operation. Follow the instructions precisely as described herein.  
The devices are only to be used, maintained and serviced by persons familiar 
with these operating instructions and in accordance with local regulations 
applying to Health & Safety and prevention of accidents.  
 
When used in machines, the measuring unit should be used only when the 
machines fulfil the EU-machine guidelines. 
 
 
 

3. Instrument  Inspection 

Instruments are inspected before shipping and sent out in perfect condition.  
Should damage to a device be visible, we recommend a thorough inspection of 
the delivery packaging. In case of damage, please inform your parcel service / 
forwarding agent immediately, since they are responsible for damages during 
transit. 
 

Scope of delivery: 

The standard delivery includes: 

 Plug-On Display  model: AUF-1.../AUF-3.../AUF-4... 

  Operating Instructions  

 
 
 

4. Regulation  Use 

Any use of the Plug-On Display, model: AUF-..., which exceeds the 
manufacturer’s specification, may invalidate its warranty. Therefore any resulting 
damage is not the responsibility of the manufacturer. The user assumes all risk 
for such usage.  
 
 
 

Summary of Contents for AUF-1 series

Page 1: ...Operating Instructions for Plug On Display Model AUF 1 AUF 3 AUF 4...

Page 2: ...Mechanical Connection 4 7 Electrical Connection 5 8 Commissioning 7 9 Technical Information 10 10 Order Codes 11 11 Dimensions 11 12 Declaration of Conformance 12 Manufactured and sold by Kobold Messr...

Page 3: ...3 Instrument Inspection Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In...

Page 4: ...decimal point gate time and switch point optional may be set with two keys The menu steps are output to the LED display field The Auf 4000 transforms the input pulses into a 4 20mA output signal 6 Me...

Page 5: ...Output 4 20 mA 2 wire 4 20 mA 2 wire switch out 4 20 mA 3 wire 4 20 mA 3 wire Auxiliary power only AUF 1 The auxiliary power typically 24 VDC must be greater than the voltage drop across the sensor t...

Page 6: ...nnection example AUF 1001 Connection example AUF 3000 AUF 4000 If the signal output is not used the signal output PIN 3 needs to be short circuited with GND PIN 2 Vs S 1 2 3 PE Switch Out GND S Ub Ua...

Page 7: ...isplayed Press A B to enter adjustment menu Press B or A for up and down Press A B to acknowledge setting and return to menu item dP 8 3 Zero Point value to be displayed for 4 mA Press key B until is...

Page 8: ...1 5 sec Press A B to acknowledge setting and return to menu item FILt 8 6 Range Exceeded indication of less than 4 mA or greater than 20 mA Indicates HI if the upper limit or LO if the lower limit is...

Page 9: ...001 optional Press key B until is displayed Press A B to enter adjustment menu hysteresis via switching point inverse Press B or A for up and down hysteresis below switching point Press A B to acknowl...

Page 10: ...load max 250 Max current load max 60 mA Conversion rate Three measurements s Gate time 0 3 20 s adjustable Data back up Non volatile EEPROM Error message HI overrange LO underflow Programming With two...

Page 11: ...4 20mA 2 wire AUF 1001 Plug on display with open collector 4 20mA 2 wire AUF 3000 Plug on display 4 20 mA 3 wire AUF 4000 Plug on display input pulses output 4 20 mA 3 wire Special Operating Instructi...

Page 12: ...with the standards noted below EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements Also the following EU guidelines are fulfill...

Reviews: