Koblenz 5007-IR Operating Instructions Manual Download Page 4

IMPORTANT: Voltage spikes may damage

your computer through the telephone line, in

order to protect your computer connect the

telephone  cable  to  the  RJ11/RJ45  outlet

located on the back of the battery backup.

Telephone Line

to RJ11/RJ45

Electrical

Outlet

USB Port

Telephone

PC

UPS

Backside

     VI. TROUBLESHOOTING
Use the table below to solve minor UPS installation or operation problems.

POSSIBLE CAUSE

POSSIBLE SOLUTION

UPS will not turn on.

UPS not properly plugged in. 

Firmly plug UPS into an appropriate electrical outlet.

UPS circuit breaker "tripped".

Reset the circuit breaker (on back of the UPS) by pushing the button in.

UPS operates on battery although normal utility voltage exists.

The outlet where the UPS is plugged in, does not supply utility voltage. Connect the UPS to another wall outlet, or have a qualified electrician check the wiring.
UPS does not provide expected backup time.

The UPS has excessive load. 

Unplug non essential connected equipment from battery backup outlets such as fax 

machines, scanners, etc. They can be plugged into surge protection outlets.

The UPS' battery is discharged.

Charge the battery, connecting and turning the UPS on. Typically eight hours are 

needed to totally recharge the battery from total discharge.

The UPS' battery needs to be replaced.

If the "REPLACE BATTERY" indicator is lit, battery should be replaced. If the UPS is 

operated with a weakened battery, runtime will be significantly reduced.

An indicator is lit.

The overload indicator is lit if the equipment connected to battery

Move one or more pieces of equipment to the surge protection outlets.

backup outlets needs more power than the UPS can provide.

The replace battery indicator is lit if the battery is near to the end

The battery should be replaced.

of its useful life.

The replace suppressor indicator is lit if a spike has burnt out 

Take the UPS to a service center or connect a surge suppressor to it. The UPS continues

the surge suppressor.

working normally.

UPS does not supply power to the computer/monitor during an outage.

Computer / monitor is plugged into a surge protector outlet.

Move computer / monitor to a battery backup outlet.

     VII. SPECIFICATIONS - TABLE 1

Outlets

Model

VA / W

Battery

Surge

Fax/Modem USB Coaxial

Regulator

Volts 

Volts 

Frec.

Weight  Batteries

Backup Protection Protection

Port

Cable

included

in

out

Hz

lbs

7507-USB/R 750/500

4

3

Yes

Yes

Yes

Yes

120 V~

120 V~ 

±

10%

60

24,2

2

7507-IR

750/500

4

3

Yes

No

No

Yes

120 V~

120 V~ 

±

10%

60

24,2

2

5007-USB/R 500/325

4

3

Yes

Yes

Yes

Yes

120 V~

120 V~ 

±

3%

60

14,6

1

5007-IR

500/325

4

3

Yes

No

Yes

Yes

120 V~

120 V~ 

±

3%

60

14,6

1

5007-I

500/325

4

3

Yes

No

No

No

120 V~

120 V~ 

±

3%

60

14,6

1

3007-IR

300/200

2

2

Yes

No

No

Yes

120 V~

120 V~ 

±

3%

60

11,8

1

3007-I

300/200

2

2

Yes

No

No

No

120 V~

120 V~ 

±

3%

60

11,8

1

     VIII. TYPICAL RUN TIME (MINUTES) - TABLE 2

IX. SAMPLE EQUIPMENT REQUIREMENTS - TABLE 3

Model

With PC and 15" monitor

Battery reserve 

Pentium III with 17" monitor

150 VA

"continuous" beep alarm

Pentium IV with 17" monitor

150 VA

7507-USB/R

Up to 60 minutes

2 - 3 minutes

Mac G3 with 19" monitor

200 VA

7507-IR

Up to 60 minutes

2 - 3 minutes

Mac G4 with 19" monitor

200 VA

5007-USB/R

Up to 24 minutes

2 - 3 minutes

34 " Television

190 VA

5007-IR

Up to 24 minutes

2 - 3 minutes

T.V. and DVD

250 VA

5007-I

Up to 24 minutes

2 - 3 minutes

Audio System

180 VA

3007-IR

Up to 17 minutes

2 - 3 minutes

3007-I

Up to 17 minutes

2 - 3 minutes

     X. DRAWING A

return it freight prepaid.

This warranty is the sole warranty of Koblenz, and there are no other warranties, expressed,

or otherwise except as required by law. Among the excluded warranties are the implied

warranty of merchantability and implied warranty of fitness for a particular purpose. Implied

warranties, if any, are limited in duration to the term of this warranty. Some states do not

allow limitations on how long an implied warranty lasts, so the above limitation may not

apply to you.

Koblenz will in no event be liable for any direct, indirect, special, incidental or consequential

damages or losses whatsoever and Koblenz's liability under no circumstances will exceed

the contract price for the goods or parts for which liability is claimed. Some states do not

allow the exclusion or limitation of incidental or consequential damages, so the above

limitation or exclusion may not apply to you.

This limited warranty applies only to the original purchaser. Proof of purchase will be

required.

     XI. WARRANTY

This warranty gives you specific legal rights, and you may have other rights which may

vary from state to state.

This product is warranted against defects in material and workmanship for a period of five

(5) years from the date of purchase with the exception of the battery which is warranted

for two (2) years. After this two year period Koblenz will replace the battery free of charge

for up to three (3) additional years for $29.99 to cover shipping and handling costs.

This warranty shall not apply to any products or parts thereof which have been damaged

by tampering, misuse or abuse or which have been altered or repaired by an unauthorized

person or service center.

For repair, the inoperative product must be delivered with shipping and delivery charges

prepaid, together with satisfactory evidence of the purchase date to our authorized

representative for handling claims indicated below. Koblenz will either repair or replace,

at its election, all defective product and / or the battery during the warranty period and

Summary of Contents for 5007-IR

Page 1: ...a batería está a punto de agotarse el tono cambia a forma continua En caso de que tenga instalado el Koblenz Protek Software y conectado el cable USB no incluido aparecerá en el monitor el siguiente mensaje BATERÍA ACTIVADA y el software realizará el cierre automático archivar y apagar antes de que la batería se termine III INDICADORES VISUALES LED Ubicados en el panel frontal del no break cada in...

Page 2: ... 60 minutos 2 3 minutos Mac G3 con monitor de 48 26 cm 19 200 VA 7507 IR Hasta 60 minutos 2 3 minutos Mac G4 con monitor de 48 26 cm 19 200 VA 5007 USB R Hasta 24 minutos 2 3 minutos Fax máquina de escribir y calculadora 600 VA 5007 IR Hasta 24 minutos 2 3 minutos T V hasta 86 36 cm 34 190 VA 5007 I Hasta 24 minutos 2 3 minutos T V y DVD 250 VA 3007 IR Hasta 17 minutos 2 3 minutos Equipo de audio ...

Page 3: ...ATTERY light will flash As the battery depletes the pace of the beep will become faster If you have installed the Koblenz Protek Software and the USB cable you will also receive a warning message on your computer screen and the software will automatically save your files and shut down your system before the battery runs out III STATUS INDICATORS Placed on the front panel to indicate UPS status 1 O...

Page 4: ...Yes No No No 120 V 120 V 3 60 14 6 1 3007 IR 300 200 2 2 Yes No No Yes 120 V 120 V 3 60 11 8 1 3007 I 300 200 2 2 Yes No No No 120 V 120 V 3 60 11 8 1 VIII TYPICAL RUN TIME MINUTES TABLE 2 IX SAMPLE EQUIPMENT REQUIREMENTS TABLE 3 Model With PC and 15 monitor Battery reserve Pentium III with 17 monitor 150 VA continuous beep alarm Pentium IV with 17 monitor 150 VA 7507 USB R Up to 60 minutes 2 3 mi...

Reviews: