Table 4: HPU200 Wiring Connections
Voltage
Rotation
Direction
L1
L2
Join Together
(Short)
115 VAC
CCW
T1, T3, T8
T2, T4, T5
--
CW
T1, T3, T5
T2, T4, T8
--
230 VAC
CCW
T1
T4, T5
T2, T3, T8
CW
T1
T4, T8
T2, T3, T5
3.3.3
Example Connection Diagrams
The following section contains various example methods for connection of the HPU.
It is recommended that installation work is carried out by a Kobelt
Partner, authorized service representative, or trained installation
technician. Please contact the nearest Kobelt authorized distributor
for assistance.
Figure 8: HPU200 Jog Control Diagram, Common Negative