background image

7180 Rudder Angle Indicator

 

 

    

Kobelt Manufacturing Co. Ltd. 

 

 

Rev B

 

 

MNL_7180

 

4 of 24 

1

 

I

NTRODUCTION

 

1.1

 

C

ONTACT

 

Kobelt Manufacturing Co. Ltd. 

8238 129th Street 

Surrey, British Columbia 

Canada, V3W 0A6 

Sales Tel:  

Fax: 

Email:  

Website:  

+1-604-572-3935 
+1-604-590-8313 

[email protected] 
www.kobelt.com

 

This document is intended to clearly present comprehensive product data and provide 
technical information to assist the end user in design applications. Kobelt reserves the right, 
without notice, to change the design, or construction, of any products and to discontinue or 
limit distribution of any products. Kobelt also reserves the right to change, or update, without 
notice, any technical information contained within this document.  

Kobelt recommends that customers visit our website to check for updates to this Manual. 
Once a product has been selected for use, it should be tested by the user to ensure proper 
function in all possible applications. For further instructions, please contact our distributors or 
visit our website.  

1.2

 

S

AFETY

 

1.2.1

 

Safety Alerts 

Throughout this manual, the following symbols, and their accompanying explanation, are 
used to alert the user to special instructions concerning a service or operation that may be 
hazardous if performed incorrectly or carelessly. The associated risk levels are stated below. 

 

This symbol indicates an imminently hazardous situation which, if 
not avoided, will result in death or serious injury.

 

 

This symbol indicates a potentially hazardous situation which, if not 
avoided, could result in death or serious injury.

 

 

This symbol indicates a hazardous situation, which if not avoided, 
could result in minor or moderate injury.

 

 

This symbol informs the reader of events not related to personal 
injury but which there is a risk of damage to property or equipment. 

 

This symbol informs the reader of safety-related instructions or 
procedures. 

Summary of Contents for 7180 Series

Page 1: ...Kobelt Manufacturing Co Ltd 7180 Rudder Angle Indicator Owner s Operation Installation Maintenance Manual February 2019...

Page 2: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 2 of 24 NOTES RECORD DATA BEFORE INSTALLATION FOR FUTURE REFERENCE Model Serial Date of Purchase Date of Installation...

Page 3: ...l Data 7 3 Operation 8 4 Installation 9 4 1 Mechanical 9 4 2 Electrical 10 5 Commissioning 15 5 1 Electrical Check 15 5 2 Calibration and Adjustment 15 5 3 Functional Test 17 6 Maintenance 18 6 1 Prev...

Page 4: ...ed for use it should be tested by the user to ensure proper function in all possible applications For further instructions please contact our distributors or visit our website 1 2 SAFETY 1 2 1 Safety...

Page 5: ...are familiar with the assembly installation commissioning and operation of the product and who have the qualifications necessary for their occupation Observe all specifications in this manual If thes...

Page 6: ...position of your rudder while your vessel is underway Whether you are manoeuvring or your autopilot is commanding your vessels an accurate readout of your rudder position will be displayed on this tri...

Page 7: ...XIMUM CURRENT METER 20 mA 40 mA RECOMMENDED DRIVING POTENTIOMETER 1k MAXIMUM NUMBER OF SLAVE UNITS 5 FACE DIAMETER 2 BULB TYPE T3 1 4 Wedge Type MAXIMUM CURRENT BULB 330 mA 60 mA 330 mA 60 mA PROTECTI...

Page 8: ...sition on the Indicator This position can be calibrated to correspond to physical rudder position or the position of an alternative signal source A single master unit can drive up to 5 slave units The...

Page 9: ...ind the panel or dash installation location to allow for securing the tightening clamps to hold the unit securely 4 1 1 Mounting A pre installed bracket and fasteners are included with 7180 gauges for...

Page 10: ...nments Control signals shown in the following figures are provided by standard control levers Please review the Kobelt website for all options available Electrical installation of the 7180 should proc...

Page 11: ...tions Master Gauge Pin Designator Pin Type Function GND Power Power Supply Common connection point V Power Power Supply Source Accepts either 12VDC or 24VDC R Output Supplies power to the positive ter...

Page 12: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 12 of 24 4 2 2 Master Unit Configuration Figure 4 Master Unit Configuration...

Page 13: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 13 of 24 4 2 3 Master and Single Slave Unit Configuration Figure 5 Master and Single Slave Unit Configuration...

Page 14: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 14 of 24 4 2 4 Master and Multiple Slave Units Configuration Figure 6 Master and Multiple Slave Units Configuration...

Page 15: ...avoid damaging the 7180 electronics use a non conductive screwdriver or other equivalent tool to adjust the trimpot or zeroing lever Exercise caution when reaching in with the screwdriver Do not let...

Page 16: ...units are added in series Do not press down on the potentiometer as this can damage the circuitry 5 2 2 Zero Adjustment The zero adjustment lever is located inside the lightbulb cavity and can be acc...

Page 17: ...Functional testing should be done by qualified personnel only The system functionality should be fully tested dockside before an open water sea trail is performed to ensure proper response of the sys...

Page 18: ...Ensure calibration and zero point of unit 6 2 RECOMMENDED SPARE PARTS As a minimum Kobelt recommends the following spare parts are on hand Table 4 Recommended Spares RECOMMENDED SPARES QTY ITEM KOBELT...

Page 19: ...uately illuminated Master indicator moves in opposite direction to rudder Potentiometer power wires are reversed Reverse the wiring at the positive and negative terminals of the potentiometer Correct...

Page 20: ...ntification of a potential issue or defect with a Kobelt Product or Part the Warranty Applicant Applicant must immediately contact Kobelt and describe the issue in writing by letter fax email or other...

Page 21: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 21 of 24 9 APPENDIX A INSTALLATION DIMENSIONS Figure 8 Mechanical Dimensions of 7180...

Page 22: ...7180 Rudder Angle Indicator Kobelt Manufacturing Co Ltd Rev B MNL_7180 22 of 24 Page Intentionally Left Blank...

Page 23: ...B MNL_7180 23 of 24 10 APPENDIX B INSTALLATION CUT OUT TEMPLATE Scale may not be exactly 1 1 due to PDF and printer scaling settings Verify primary dimension with a ruler after printing and before us...

Page 24: ...lt Manufacturing Co Ltd 8238 129th Street Surrey British Columbia Canada V3W 0A6 Sales Tel 1 604 572 3935 Fax 1 604 590 8313 Email sales kobelt com Website www kobelt com Made in Canada Printed in Can...

Reviews: