     TROUBLESHOOTING 

 

 

 

Problem

 

 

 

 

Action

 

 

ƒ

 

Indicator(s) not operational 

ƒ

 

Master indicator moves in opposite     

direction to rudder 

ƒ

 

Secondary indicator moves in opposite 

direction to rudder 

ƒ

 

Port and Starboard hardover to hardover 

are not equal 

ƒ

 

Indicator(s) movement not in sequence 

with rudder movement 

 

Check for proper wiring and fuse 
Reverse wires V+ and V- at respective 

terminals 

Reverse wires as above 

 

Rudder angle feedback unit 7174 / 7168 not 

installed or adjusted properly 

Calibrate linkage to obtain desired stroke / 

calibrate span 

 

 

 

 