6
Ductwork Installation
5.
Use 6” round steel pipe (not provided) to
connect the plastic exhaust on the hood to
the ductwork above. Use duct tape to make
all joints secure and air tight.
Refer to Figure 4.
THIS RANGE HOOD MUST BE
PROPERLY GROUNDED. MAKE SURE
THIS
IS
DONE
BY
QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH
ALL APPLICABLE NATIONAL AND LOCAL
ELECTRICAL
CODES.
BEFORE
CONNECTING WIRES, SWITCH POWER
OFF AT SERVICE PANEL AND LOCK
SERVICE PANEL TO PREVENT POWER
FROM
BEING
SWITCHED
ON
ACCIDENTALLY.
-
If hood is operating normally, connect three
wires (black, white and green) to house
wires and cap with wire connectors.
-
Store wires in the wiring box.
Duct Cover Installation
NOTE:
BE
CAREFUL
WHEN
USING
ELECTRICAL SCREWDRIVER, DAMAGE TO
THE HOOD MAY OCCUR.
6.
Using reference E from Table 1 and
measurements on pages 11-12, mark the
leveling point for duct cover bracket.
7.
Secure the duct cover mounting bracket to
the wall with two screws (not provided).
Make sure all screws are tightened Refer to
Figure 5. NOTE: Inner duct cover will cover
the duct cover bracket.
8.
Slide the entire duct cover onto the hood.
Refer to Figure 6.
Figure 4
Figure 5
Figure 6
Wiring to Power Supply
Summary of Contents for CHX8130SQB-1
Page 15: ...12 Inner RA0930DC Inner RA0946DC Model No RA0930DC Model No RA0946DC...
Page 16: ...13 PARTS LIST MODEL NO CHX8130SQB 1 30 CHX8136SQB 1 36 MRH CHX8130SQB 30 MRH CHX8136SQB 30...
Page 17: ...14 MODEL NO CHX8130SQB 1 CHX8136SQB 1 CHX8130SQB 1 CHX8136SQB 1...
Page 18: ...15 CIRCUIT DIAGRAM MODEL NO CHX8130SQB 1 CHX8136SQB 1 Q...