Wiring to Power Supply 

CAUTION

:    If  moving  the  cooking  range  is 

necessary to install the hood, turn off the power in 
an electric range at the main electrical box.  SHUT 
OFF  THE  GAS  BEFORE  MOVING  A  GAS  RANGE. 
RISK OF ELECTRICAL SHOCK.   

 THIS  RANGE  HOOD  MUST  BE  PROPERLY 

GROUNDED.    MAKE  SURE  THIS  IS  DONE  BY 
QUALIFIED  ELECTRICIAN  IN  ACCORDANCE  WITH 
ALL 

APPLICABLE 

NATIONAL 

AND 

LOCAL 

ELECTRICAL  CODES.    BEFORE  CONNECTING 
WIRES,  SWITCH  POWER  OFF AT  SERVICE  PANEL 
AND LOCK SERVICE PANEL TO PREVENT
 POWER 
FROM BEING SWITCHED ON ACCIDENTALLY. 
 
8.  If  hood  is  operating  normally,  connect  three  wires 

(black,  white  and  green)  to  house  wires  and  cap 
with wire connectors.   

9.  Store wires in the wiring box. 
 

Ductwork Installation 

 

10. Use steel pipe to connect the exhaust on the hood 

to the  ductwork.   Use  duct tape to make  all  joints 
secure and air tight.   
 

Duct Cover Installation 

 
11. Mark  the  position  of  the  Duct  Cover-Mounting 

Bracket  {N}.    Use  reference  E  from  Table  2  and 
measurements  on  page 17-18.   Attach  and  secure 
Duct  Cover-Mounting  Bracket  {N}  with  two  screws 
(provided).   Refer to  Figure  17.    NOTE:  Inner  duct 
cover will cover the Duct Cover-Mounting Bracket. 

12. Position the entire duct cover up onto the hood. 
13. Secure the inner duct cover with two (3/16” x 3/8”) 

screws {M} to the Duct Cover-Mounting Bracket {N}. 
Shown in Figure 18. 

14. Fasten outer duct cover to Duct Cover Support {O} 

with four (4 x 6 mm) screws {M}. 
     
 
 
 
 
 

 

  Figure 17 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 18 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 

Attach Together 

Summary of Contents for CH7736SQB-1

Page 1: ...KOBE Range Hoods Premium Series CH77 SQB 1 Series Model No Under Cabinet CH7736SQB 1 36 Wall Mount CH7736SQB WM 1 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Page 2: ...IT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shipping damages co...

Page 3: ...E 15 SPECIFICATIONS 16 MEASUREMENTS DIAGRAMS 17 PARTS LIST 19 CIRCUIT DIAGRAM 21 TROUBLE SHOOTING 22 WARRANTY 23 WARRANTY INFORMATION FORM 25 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I...

Page 4: ...atment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automati...

Page 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Page 6: ...2 36 hood I Stainless Steel Spacer x 2 J Wire Cap x 3 K Screw Package for Under Cabinet only A B C D E F G H I J K L Adjustable Duct Cover M Screws Package N Duct Cover Mounting Bracket O Duct Cover...

Page 7: ...o Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVE...

Page 8: ...SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Conten...

Page 9: ...ure 2 Using reference on Page 17 to measure and create access opening for electrical wires and exhaust under the cabinet Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS...

Page 10: ...the front of the cabinet 7 Draw electrical wires through cabinet access opening 8 Use electrical drill to remove the knockout holes on top of the range hood 9 Place screw provided into the exact cente...

Page 11: ...Filters H and Stainless Steel Spacers I Angle baffle filter toward back of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Sli...

Page 12: ...or secure installation Using references on Table 2 and measurements on page 17 18 decide the level of the lumber Refer to Figure 10 Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIG...

Page 13: ...er Figure 14 Hood Installation CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A...

Page 14: ...house wires and cap with wire connectors 9 Store wires in the wiring box Ductwork Installation 10 Use steel pipe to connect the exhaust on the hood to the ductwork Use duct tape to make all joints se...

Page 15: ...of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting position Refer to Figure 20 17 For Sta...

Page 16: ...the 3 minute countdown To turn fan off immediately press button a second time Light Control Press button to turn LED lights ON Each press of button will cycle the light intensity through Bright Mediu...

Page 17: ...ash while ECO Mode is operating on QuietMode To deactivate press and hold button until icon no longer appears in the LED Display NOTE Pressing button while ECO Mode is active will activate the regular...

Page 18: ...orn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface...

Page 19: ...0 minutes every hour to remove excess moisture microscopic particles and odors to promote a cleaner kitchen environment LIGHTS 3 Level Lighting 3 watt LED light x 2 36 HOOD DIMENSION W x D x H CH7736S...

Page 20: ...rements are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO CH7730SQB 1 30 36 Knockout Holes A B FOR WALL MOUNT DUCT COVER...

Page 21: ...18 Hood Mounting Bracket Duct Cover Mounting Bracket Duct Cover Support...

Page 22: ...B L1 0301 0120 102B 12 Motor A L1 0301 0120 102A 13 Turbine Impeller B L1 0251 0747 B 14 Tubine Impeller A L1 0251 0747 A 15 Processor Board L1 0404 6001 B 16 Plastic Oil Tunnel L1 0502 0102 17 Safety...

Page 23: ...20 MODEL NO CH7736SQB 1 and CH7736SQB WM 1 36...

Page 24: ...21 CIRCUIT DIAGRAM MODEL NO CH7736SQB 1 and CH7736SQB WM 1 36...

Page 25: ...ng bracket The motor is working but the lights are not working LED light fixture s is defective Replace LED light fixture s The light wiring s is loose Check wire continuity from processor board to li...

Page 26: ...ited States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited Th...

Page 27: ...nsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY SERVICE PLEASE CONTACT...

Page 28: ...odel No 3 Serial No For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE...

Page 29: ...mand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votre propr...

Reviews: