background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY WARNING 

HOOD  MAY  HAVE  VERY  SHARP  EDGES;  PLEASE  WEAR  PROTECTIVE  GLOVES  IF 
REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. 

 
NOTE:  BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY 

OCCUR. 

 

 

Installation Contents 
 
 

 
UNDER THE CABINET  
WALL MOUNT  
 

 


 

Summary of Contents for CH77 SQB-5 Series

Page 1: ...KOBE Range Hoods Deluxe Series CH77 SQB 5 Series Model No Under Cabinet CH7736SQB 5 36 Wall Mount CH7736SQB WM 5 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ...NIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shipping damages cosmetic damages or defects 4 For all other issues email customer service koberangehoods com or call 1 626 775 8880 ext 103 toll free 1 877 289 5623 NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEE...

Page 3: ...CE 15 SPECIFICATIONS 16 MEASUREMENTS DIAGRAMS 17 PARTS LIST 19 CIRCUIT DIAGRAM 21 TROUBLE SHOOTING 22 WARRANTY 23 WARRANTY INFORMATION FORM 25 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Page 4: ...eatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hoo...

Page 5: ...you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufacturer s...

Page 6: ...rs x 2 36 hood I Stainless Steel Spacer x 2 J Wire Cap x 3 K Screw Package for Under Cabinet only A B C D E F G H I J K L Adjustable Duct Cover M Screws Package N Duct Cover Mounting Bracket O Duct Cover Support x 2 P Hood Mounting Bracket Q Screws Package for Wall Mount only L M N O P Q FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www koberangehoods com OR CONTACT KOBE RANGE HOODS AT 626 775 888...

Page 7: ...to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of Duct Cover F D F Hei...

Page 8: ...Y SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents UNDER THE CABINET WALL MOUNT 6 9 ...

Page 9: ...gure 2 Using reference on Page 17 to measure and create access opening for electrical wires and exhaust under the cabinet Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD 1 Choose the require vent option Some installation screws are already pre attached to hood 2 For 6 Round vent installation only The 6 exhaust is already attached Figu...

Page 10: ... the front of the cabinet 7 Draw electrical wires through cabinet access opening 8 Use electrical drill to remove the knockout holes on top of the range hood 9 Place screw provided into the exact center of each knockout hole Make sure all screws are in place before tightening screws CAUTION MAKE SURE THE HOOD IS SECURE BEFORE RELEASING Wiring to Power Supply CAUTION If moving the cooking range is ...

Page 11: ...e Filters H and Stainless Steel Spacers I Angle baffle filter toward back of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting position Refer to Figure 8 13 For Stainless Steel Spacer follow above steps Final Installation 14 Turn power ON in control panel Check all lights and fan operation ...

Page 12: ...for secure installation Using references on Table 2 and measurements on page 17 18 decide the level of the lumber Refer to Figure 10 Vent option installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD 1 Choose the require vent option Some of installation screws are already pre attached to hood Refer to Figure 15 Please use Screws Package M with pre attac...

Page 13: ...ver Figure 14 Hood Installation CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE And use a protective covering to protect cooktop and or countertop from damage 5 Secure Hood Mounting Bracket P and two Duct Cover Support O on top of the hood with eight pre attached screw...

Page 14: ...o house wires and cap with wire connectors 9 Store wires in the wiring box Ductwork Installation 10 Use steel pipe to connect the exhaust on the hood to the ductwork Use duct tape to make all joints secure and air tight Duct Cover Installation 11 Mark the position of the Duct Cover Mounting Bracket N Use reference E from Table 2 and measurements on page 17 18 Attach and secure Duct Cover Mounting ...

Page 15: ... of hood Push the baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting position Refer to Figure 20 17 For Stainless Steel Spacer follow above steps Final Installation 18 Turn power ON in control panel Check all lights and fan operation 19 Make sure to leave this manual for the homeowner Figure 19 Figure 20 ...

Page 16: ...g the 3 minute countdown To turn fan off immediately press button a second time Light Control Press button to turn LED lights ON Each press of button will cycle the light intensity through Bright Medium Bright Dim and OFF Lights are controlled independently from Power Control and delay shutoff Turning the power off will not turn lights off ECO Mode Control ECO Mode is set to turn fan on QuietMode ...

Page 17: ...lash while ECO Mode is operating on QuietMode To deactivate press and hold button until icon no longer appears in the LED Display NOTE Pressing button while ECO Mode is active will activate the regular fan function and the speed will be displayed in LED Display Note Must open door or windows to create sufficient make up air when ECO Mode has been activated ...

Page 18: ...born spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals ...

Page 19: ...10 minutes every hour to remove excess moisture microscopic particles and odors to promote a cleaner kitchen environment LIGHTS 3 Level Lighting 3 watt LED light x 2 36 HOOD DIMENSION W x D x H CH7736SQB 5 and CH7736SQB WM 5 35 3 4 x 22 x 10 OPTIONAL ACCESSORIES W x D x H 1 Two Piece Adjustable Duct Cover Included in Wall Mount Hood CH1120DC 1 11 13 16 x 10 7 16 x min 22 max 41 2 36 Stainless Stee...

Page 20: ...urements are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO CH7736SQB 5 36 36 Knockout Holes A B FOR WALL MOUNT DUCT COVER IS INCLUDED MODEL NO CH7736SQB WM 5 36 ...

Page 21: ...18 Hood Mounting Bracket Duct Cover Mounting Bracket Duct Cover Support ...

Page 22: ...X5 L1 0301 0120 102B 12 Motor A X5 L1 0301 0120 102A 13 Turbine Impeller B L1 0251 0747 B 14 Tubine Impeller A L1 0251 0747 A 15 Processor Board L1 0404 6001 B 16 Plastic Oil Tunnel L1 0502 0102 17 Safety Screen L1 0602 0101 18 Safety Screen Screws L1 0705 0001 19 Stainless Steel Spacer 4 5 16 109 x14 3 8 365 CH7736SQB 5 B101 9136 15 20 Baffle Filter L1 0214 0191 Duct Cover Included in CH77 SQB WM...

Page 23: ...20 MODEL NO CH7736SQB 5 and CH7736SQB WM 5 36 ...

Page 24: ...21 CIRCUIT DIAGRAM MODEL NO CH7736SQB 5 and CH7736SQB WM 5 36 ...

Page 25: ...ing bracket The motor is working but the lights are not working LED light fixture s is defective Replace LED light fixture s The light wiring s is loose Check wire continuity from processor board to light transformer to LED light fixture s The control panel or processor board is defective Replace the control panel or processing board The range hood is not venting out correctly The range hood is in...

Page 26: ...ted States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited There may be additional shipping charges for parts and service technician travel costs in remote areas or locations 30 miles outside of KOBE authorized service area WHAT IS NOT COVERED 1 Normal wear and ...

Page 27: ...onsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY SERVICE PLEASE CONTACT KOBE RANGE HOODS SERVICE CENTER From the 48 contiguous states Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE 289 5623 From Alaska Hawaii and Cana...

Page 28: ...Model No 3 Serial No For warranty service or spare parts purchase in US contact KOBE Service Center Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Toll Free 1 877 BUY KOBE 289 5623 For warranty service or spare parts purchase in Canada contact Email best customer service koberangehoods com Phone 1 626 775 8880 ext 103 Your notes ...

Page 29: ...mandé d utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el...