background image

 

 9 

2. 

Align hood-mounting  bracket  to the two 

screws  on  the  wall  and hook hood into 

place.  Tighten screws to secure hood to 

the wall.   

3. 

For  safety  purposes,  extra  knockout 

holes  on  the  back  of  the  hood  are 

provided.  Knockout the holes.  Remove 

the baffle filters and attach screws to the 

wall by accessing underneath the hood.  

CAUTION:  MAKE  SURE  HOOD  IS 

SUCURE BEFORE RELEASING 

 

Wiring to Power Supply 

 

SA FETY W A RN IN G 

RISK  OF  ELECTRICAL  SHOCK.    THIS 

RANGE  HOOD  MUST  BE  PROPERLY 

GROUNDED.  MAKE SURE THIS  IS  DONE 

BY 

SPECIALIZED 

ELECTRICIAN 

IN 

ACCORDANCE  WITH  ALL  APPLICABLE 

NATIONAL  AND  LOCAL  ELECTRICAL 

CODES.    BEFORE  CONNECTING  WIRES, 

SWITCH POWER OFF AT SERVICE PANEL 

AND LOCK SERVICE PANEL TO PREVENT

 

 

POWER  FROM  BEING  SWITCHED  ON 

ACCIDENTALLY. 

4. 

Connect the electrical wires.   

Connect three wires (black, white and 

green)  to  house  wires  and  cap  with 

wire  connectors.    Connect  according 

to color:  black to black, white to white, 

and  green  to  green  as  shown  on 

Figure 12. 

If necessary to hide the electrical wire 

connections, push wires back into the 

wiring  box.    Access  the  wire 

connections  underneath  the  hood. 

Make  sure  wires  do  not  slip  between 

motor or  any  moving  parts to  prevent 

any damage.   

 

Duct Cover Installation 

 

5. 

Use  aluminum or  steel  pipe  to  connect 

the  plastic  exhaust  on  the  hood  to  the 

ductwork above.  Use duct tape to make 

all  joints  secure  and  air  tight as  shown 

on Figure 13. 

6. 

To  convert  ductwork  to  7”  round, 

attached 7” round adapter (provided) to 

the 6” round plastic exhaust.. 

7. 

For  48”  hood,  prepare  either  separate 

parallel connection or upside down Y- 

Connection 

for 

proper 

ductwork 

installation.  Refer to Figure 14. 

 

Figure 12 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 13 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 14 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CH0030SQB

Page 1: ...KOBE Brand Range Hood Model No CH0030SQB CH0036SQB CH0042SQB CH0048SQB CH 100 SERIES 18 HEIGHT INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ... Instructions 11 Maintenance 12 Specifications 13 Measurements Diagrams 14 Parts List 16 Circuit Diagram 21 Disclaimer 23 Warranty 24 Product Registration 26 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A LL W IRING M UST B E DO N E BY A PRO FES SIO NAL AND IN A CCO R DAN CE W ITH NA TIO NAL A ND LO CAL ELECTRICAL CO DES ...

Page 3: ...oper use mistreatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by...

Page 4: ...o not try to turn on the lights or any type of appliance Open all doors and windows to disperse the gas If you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork 3 Follow the heating equipment manufacturer s guideline and...

Page 5: ...ound Adapter 1 Option of Model No CH0030DC 12 for 30 hood KOBE Duct Cover 1 Screw Package 1 Hood Mounting Bracket 2 Model No CH0036DC 12 for 36 hood KOBE Duct Cover 1 Screw Package 1 Hood Mounting Bracket 2 Model No CH0042DC 12 for 42 hood KOBE Duct Cover 1 Screw Package 1 Hood Mounting Bracket 2 Model No CH0048DC 12 for 48 hood KOBE Duct Cover 1 Screw Package 1 Hood Mounting Bracket 2 OPTIONAL RE...

Page 6: ...E 1 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Recommended 27 to 30 D Height of Hood E Height of the Cabinet FOR STAND ALONE WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Recommended 27 to 30 A B D E D Height o...

Page 7: ...DGES PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents Under the Cabinet 6 Stand Alone 8 ...

Page 8: ...er to Figure 2 Measure and create access opening for electrical wires and plastic exhaust under the cabinet Hood Installation CAUTION If required to move the cooking range to install the hood turn off the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE 1 Puncture the knockout holes on the hood as shown in Figure 3 2 Using references on Table 1 and m...

Page 9: ...G WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 9 Connect the electrical wires Connect three wires black white and green to house wires and cap with wire connectors Connect according to color black to black white to white and green to green as shown on Figure 6 If necessary to hide the electrical wire connections push wires back...

Page 10: ...g references on Table 2 and measurements on page 14 15 decide the level of the lumber Refer to Figure 9 Hood Preparation before Installation Temporarily wire the hood to test for proper operation before installing Important Peel protective film off the hood and the duct cover if any Attach the two hood mounting brackets to the back of the hood with 3 16 x 3 8 screws provided as shown In Figure 10 ...

Page 11: ... ON ACCIDENTALLY 4 Connect the electrical wires Connect three wires black white and green to house wires and cap with wire connectors Connect according to color black to black white to white and green to green as shown on Figure 12 If necessary to hide the electrical wire connections push wires back into the wiring box Access the wire connections underneath the hood Make sure wires do not slip bet...

Page 12: ...to Figure 15 Slide the baffle filter into the hood Push the baffle filter upward Slide forward Pull downward Fit into place 10 For bottom casing repeat above steps Refer to page 15 Final Assembly 11 Turn power ON in control panel Check all lights and fan operation 12 Make sure to leave this manual for the homeowner Figure 15 ...

Page 13: ...peeds Press Speed Control A button to cycle from Low Medium High or QuietMode Press Speed Control B button to cycle from Low QuietMode High or Medium Note Speed Control A or B will operate both fans These two speed buttons will allow you to change the speed quicker Press Light Control button to turn halogen light on Press the back Red button to turn on heating lamp Note Heating lamps are sold sepa...

Page 14: ... steel wool or steel brushes Small bits of steel may adhere to the surface causing rust 6 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth To Clean Baffle Filters CAUTION DRAIN BAFFLE FI...

Page 15: ...del No CH0030DC 12 30 x 12 x 12 Model No CH0036DC 12 36 x 12 x 12 Model No CH0042DC 12 42 x 12 x 12 Model No CH0048DC 12 48 x 12 x 12 2 Recirculating Kit Recirculating Duct Cover Model No CH0030RD 12 30 x 12 x 12 Model No CH0036RD 12 36 x 12 x 12 Model No CH0042RD 12 42 x 12 x 12 Model No CH0048RD 12 48 x 12 x 12 3 Model No SSP30 30 Stainless Steel Back Panel 30 x 1 10 x 32 4 Model No SSP36 36 Sta...

Page 16: ...All inch measurements are converted from millimeters Inch measurements are estimated FOR UNDER THE CABINET FOR STAND ALONE WITH OPTIONAL DUCT COVER MODEL NO CH0030SQB MODEL NO CH0048SQB CH0036SQB CH0042SQB MODEL NO CH0030SQB MODEL NO CH0048SQB CH0036SQB CH0042SQB ...

Page 17: ...15 Rear Knockout Holes Hood Mounting Bracket ...

Page 18: ...amp Socket C1 0414 0120 10 Safety Screen C1 0602 0103 CH0030SQB C1 0201 2130 CH0036SQB C1 0201 2136 CH0042SQB C1 0201 2142 11 Capacitor Panel CH0048SQB C1 0201 2148 CH0030SQB CH0036SQB C1 0402 0120 40 CH0042SQB 12 Transformer Light CH0048SQB C1 0402 0120 60 13 Capacitor C1 0401 0120 03 14 Transformer Motor C1 0402 A 120 01 15 Processor Board Box C1 0501 0102 16 Processor Board C1 0404 0401 B 17 Sc...

Page 19: ...D 12 C1 0241 2130 FA CH0036RD 12 C1 0241 2136 FA CH0042RD 12 C1 0241 2142 FA Box CH0048RD 12 C1 0241 2148 FA CH0030RD 12 C1 0241 2130 FB CH0036RD 12 C1 0241 2136 FB CH0042RD 12 C1 0241 2142 FB Box Bracket CH0042RD 12 C1 0241 2148 FB Box Panel Left C1 0209 2130 FA 03 A B C Right C1 0209 2130 FB 04 Screw 3 16 x 3 8 C1 0707 0001 05 Aluminum Pipe C1 0601 0004 06 6 Round Plastic Exhaust C1 0505 0001 CH...

Page 20: ...18 MODEL NO CH0030SQB CH0036SQB ...

Page 21: ...19 MODEL NO CH0042SQB ...

Page 22: ...20 MODEL NO CH0048SQB ...

Page 23: ...21 CIRCUIT DIAGRAM MODEL NO CH0030SQB CH0036SQB ...

Page 24: ...22 MODEL NO CH0042SQB CH0048SQB ...

Page 25: ...t of package s Contact your local KOBE dealer or distributor or call KOBE for the time limit CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS NOTE ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR FACTORY 3 Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons fillers and shipping cartons A restocking fee of 25 will ...

Page 26: ...ovided a if the identification number attached to the range hood has been altered rendered illegible or removed b if notice of the defect has not been given within the period applicable c for failure of light bulbs d for physical damage e for surfaces damaged by use of improper chemical cleaning agents f if the appliance has been i subject to misuse abuse negligence accident incorrect installation...

Page 27: ...for purpose imposed on the sale by the laws of the state of sale are limited to two year from the date of original purchase Some states do not allow limitations on the duration of implied warranties This warranty gives you specific legal rights and may also have rights which vary from state to state SERVICE For service contact KOBE Range Hoods Inc 4934 Walnut Grove Avenue Suite 202 San Gabriel CA ...

Page 28: ...n of the original purchaser s warranty See warranty section for complete warranty coverage information This appliance has been manufactured tested and inspected to the standards required by KOBE Range Hoods PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF PURCHASE TO KOBE Range Hoods Inc 4934 Walnut Grove Avenue Suite 202 San Gabriel CA 91776 RECORD THE FOLLOWING INFORMATION FOR YOUR RE...