                            LCD Programmable Thermostat 

                                        Code: 0769006, Reference: KT6-LCD

-P 

 

A. 

Installation, Mounting: 

 

CAUTION:   

1.

 

Turn off 0769006, electronic source and the electrical devices (e.g. heater, cooler) 
which will be connected before installation and maintenance. 

2.

 

The installer must be a trained service engineer. 

 

    1.  Installation Location: 

The thermostat should be  mounted on an  inner wall 1.5m above the  floor in position 
where  it  is  readily  affected  by  changes  of  the  general  room  temperature  with  freely 
circulating air. Prevent direct exposure to sunlight; dripping or splashing area. Do not 
place  this  unit  at  a  location  where  air  circulation  is  low,  or  where  it  has  great 
temperature  changes  (e.g.  near  door).  Do  not  place  the  thermostat  near  heat/cool 
generating sources (radiators, hot air vents, TV or lights). 

 

  2.  Wiring: 

There are 3 wiring terminals at the bottom of 0769006, labeled as "COM"(Common), 
"C"(Cooler), “H” (Heater). Connect a heater to “H” terminal and connect a cooler to 
the "C” terminals. Leaves unused hole blank. 
Wire the correct cables to the terminal block according to the circuit diagram which is 
attached inside the thermostat top cover. 
Push all cables back into wall prior to fixing to avoid trapping wires. 
It  is  recommended  that  the  wiring  connection  to  the  supply  is  via  a  fuse  rated  at  no 
more than 5 Amps. (Please refer to the wiring diagram on the last page.) 

  

3.  Mounting: 

Using  the  accessory  screws  and  wall  anchors  provided,  mount  0769006  with  the 
key-hole at the back. The thermostat should be mounted on the wall as shown in step 
3 of Figure1. Install the cover on 0769006 as shown in step 4 of Figure1.   

 

Install or replace the battery: 

Caution: Turn off the electrical devices and disconnect the supply to the appliances 
before  replacing  the  batteries.  Replace  only  with  the  same  or  equivalent  type  of 
batteries.  Do  not  dispose  the  used  batteries  with  household  waste.  Refer  to  your 
local area for the proper disposal. 

 

1.

 

Pull out the battery drawer 

2.

 

Place the new batteries according to the marking on the battery drawer. 

3.

 

Dispose the old batteries properly. 

4.

 

Slide the battery drawer back to its position. 

5.

 

Check if the thermostat works properly or not. 
Press “RST” if necessary. 

 

Use a flat screwdriver 
to press on the gap at 
both sides to detach   
the front shell. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

B. 

Start/Reset: 

1.

 

After wiring and mounting, switch off all the connected devices. Place 2 new AAA 
1.5V alkaline batteries according to the polarities marked. 
LCD display will be switched on. 

2.

 

Slide the switch at the position (“

 

  “ / 

  “) which matches with the control device 

(heater/ cooler). 

3.

 

Press ‘RST’ to reset. The 0769006 will be ready to control the heater / cooler.                     

       

 

4.

 

Switch ON the heater / cooler. The heater / cooler will remain OFF 

until 0769006 activates the output ON with 

  displayed on LCD. 

 

 

C. 

Normal Time Mode:

 

1.

 

Temperature detection starts and LCD displays the room temperature. 

2.

 

If Battery is LOW, 

  will be flashing. The old batteries must be replaced with new one 

immediately.   

3.

 

Defrost function is activated with 

  displayed when temperature is 5°C or below. Output 

will be forced to ON @ Heat & OFF @ Cool. 

4.

 

Below 0°C, 0769006 will display

 LO.

 

5.

 

Above 40°C, 0769006 will display

 HI

 

D.  Normal Time Setting Mode: 

1.

 

Press 

<

>,

 the Day of Week (1-7) will flash, press 

<

>, <

>

 to select the current Day 

of Week.   

2.

 

Press 

<

>,

 the Hour will flash, press 

<

>, <

>

 to set the Hour. 

3.

 

Press 

<

>

, the Minute will flash, press 

<

>, <

>

 to set the Minute. 

4.

 

Press 

<

>

 will jump back to the step 1. 

5.

 

Press 

<

>

 to confirm the settings and return to Normal Mode. 

Or 0769006 will auto-return to normal mode after 10 seconds. 

 

E. 

 

Factory Defined Programs:

   

The heater / cooler turns on according to the activated program and the control temperature 

setting. When the heater / cooler is On, Program number and   

  / 

  icons are shown. 

 

The pre-defined programs are as below: 

Heater mode: 

 

Mon ~ Fri 

Sat 

Sun 

P1 

06:00 (21°C) 

08:00 (21°C) 

08:00 (21°C) 

P2 

08:00 (16°C) 

10:00 (16°C) 

10:00 (16°C) 

P3 

18:00 (21°C) 

18:00 (21°C) 

18:00 (21°C) 

P4 

22:00 (16°C) 

23:00 (16°C) 

23:00 (16°C) 

Cooler mode: 

 

Mon ~ Fri 

Sat 

Sun 

P1 

06:00 (24.0°C) 

08:00 (24.0°C) 

08:00 (24.0°C) 

P2 

08:00 (29.5°C) 

10:00 (29.5°C) 

10:00 (29.5°C) 

P3 

18:00 (29.5°C) 

18:00 (29.5°C) 

18:00 (29.5°C) 

P4 

22:00 (26.0°C) 

23:00 (26.0°C) 

23:00 (26.0°C) 

 

F.  Set Program: 

1.

 

Press 

<PRG>,

 the hour will flash, press 

<

>, <

>

 to change the hour setting.   

2.

 

Press 

<PRG>,

 the minutes will flash, press 

<

>, <

>

 to change the minutes setting. 

3.

 

Press 

<PRG>, 

temperature will flash, press 

<

>, <

>

 to change the setpoint. 

4.

 

Press 

<PRG>

 to set the next program. 

5.

 

The program setting sequence is as below: 
Mon~Fri (P1

 P2

 P3 

 P4)

 Sat (P1

 P2

 P3 

 P4)

   

Sun (P1

 P2

 P3 

 P4)

 

6.

 

Press 

<

>

 to exit the program mode setting and return to the normal mode. 

Or 0769006 will auto-return to normal mode after 10 seconds. 

 

G.

 

Temporary / Permanent Override Mode: 

There are two modes in the override mode (Temporary override and Permanent override 

mode). Press 

<

to select the override mode.   

The sequence is as below: 
Normal

 Temporary Override 

 Permanent Override

 Normal

… 

 

Selecting the Temporary/ Permanent Override Mode 

1.

 

Press 

<

to 

change the mode from normal to Temporary Override. 

  icon will be 

displayed. 

2.

 

Press 

<

again, the mode changes from Temporary Override to Permanent Override 

mode. 

  icon will be displayed. 

3.

 

Press 

<

once, the mode changes from Permanent Override to normal mode. 

 

 

Review and adjust the Override temperature: 

1.

 

Press 

<

>

/

<

>

, the Override temperature is shown. 

2.

 

Hold the 

<

>

/

<

for 2 seconds, the Override temperature will flash. 

3.

 

Press 

<

>

/

<

>

 to adjust the Override temperature. 

4.

 

Press 

<

>

 to exit the Override temperature setting. 

Or 0769006 will auto-return to normal mode after 10 seconds. 

Temporary Override Mode: 

Temporary override Mode maintains until next program time is met.

 

 

Permanent Override Mode: 

The room temperature will be maintained at the override temperature until 

override mode is released. Press 

<

to release the Permanent override 

mode.   

 

H.

 

Control Off / Sleep Mode: 

1.

 

Press the <

> to select the sleep mode and control off mode. The sequence is 

as below: 
Normal Mode 

 Sleep Mode 

 Control Off Mode

Normal Mode

 … 

2.

 

Press  any  other  keys  to  exit  the  control  off  /  Sleep  mode  and  return    normal 
mode. 

 

Sleep Mode: 

At  sleep  mode,  <

>

 

icon  is  displayed.  0769006  stops  measuring  and 

displaying the temperature. Only the current time is shown.   
The  heater  /  cooler  is  turned  off,  irrespective  of  the  current  control  setting 
temperature. 

 

Control Off Mode: 

The LCD is fully turned off. The heater / cooler is switched off, irrespective of 
the current control temperature setting. 

 

I.

 

Slide Switch Selection 

-   

When the slide switch is set at “

 

  “ position, the heater option is selected. 

The thermostat controls the heater “ON” or “OFF” only.

 

-   

When the slide switch is set at “ 

  “ position, the cooler option is 

selected. The thermostat controls the cooler “ON” or “OFF” only. 

 

J.

 

Jumper Selection: 

Delay / No Delay jumper: 

   

 

Heater   

Cooler 

No delay 

 

10sec   

4mins 

Delay 

 

4mins   

4mins 

Choose the Delay option if compressor heat is connected. 

 

12-hours / 24-hours mode jumper: 
When the 12-hours option is selected, the time is shown in 12-hours mode. 
Otherwise, the time is shown in 24-hours mode. 

 

K. 

 

Specification: 

1.  Temperature measurement:  0.0 - 40°C (0.1°C/step) 
2.  Accuracy:   

 

± 0.5°C 

3.  Temperature control range:    5.0 - 35.0°C (0.5°C/step) 
4.  Switching:   

   

24..250VAC 50/60Hz 5(1)A max 

5.  Terminals:                               2.5mm

2

 cable   

6.  Electronic control:                   Type 2.B action 
7.  Battery: 

 

 

2 x 1.5V AAA alkaline battery 

8.  Operating temperature: 

0 - 50°C 

9.  Storage temperature:  

0 - 50°C 

10.  Sensing element: 

 

NTC thermistor 

 

Terminal block Connecting Label: 

 
 
 
 
 
 
 
 
 
 
 
 

                       

 

TEMPER ENERGY INTERNATIONAL S.L. 
Polígono industrial de Granda, nave 18 
33199 • Granda - Siero • Asturias 
Teléfono: (+34) 902 201 292 
Fax: (+34) 902 201 303 
Email: [email protected]   

www.grupotemper.com

                                                               