Temperature offset
The temperature of internal sensor can be calibrated
from
-5
°
C - +5
°
C
in case there is temperature
difference between actual value and thermostat.
Switching Differential
The difference between
switching
the heating or
controller on and off
Program Mode:
0: No Program Mode, The thermostat control the
temperature simply according to single setpoint. 1:
1 day program, The thermostat control the
temperature according to single schedule.
2: 5+1+1 day program, The thermostat control the
temperature according to 5 +1+1 schedule (Mon to
Fri, Sat, Sun).
:
3: 7day program, The thermostat control the
temperature according to 7day program (individual
program for each day).
Adaptive control
When this function is enable, the thermostat learns
the time taken to reach the desired setpoint and turn
on the heating / cooling earlier so that the room
temperature will reach the setpoint at desired
schedule. This is no effect when
No program
is
selected.
Heat / Cool Mode
When Heat mode is selected, the thermostat control
The room temperature with heating. Room Sensor,
Floor Sensor or Combined sensor can be selected.
When Cool mode is selected, the thermostat
control The room temperature with cooling.
Only room Sensor, will be used.
Sensor Mode
There are 3 different settings of sensor control for
Heat Mode. (For Cool Mode. Only Room sensor will
be used)
- Room sensor
Thermostat controls the room temperature based on
Room sensor
Floor Sensor
Thermostat control the room temperature based on
Room Sensor. And the output will be off if floor
temperature above “floor temperature limited” for
protection.
Floor temperature limited
It is the temperature for floor sensor. When the Heat
Mode and Combined Sensor are selected. The
output will turn off when floor sensor senses the
temperature higher than the floor temperature limit.
Advanced
– Factory Default
⚫
Press-n-Hold on [Mode]+[blank] keys
⚫
Press [Mode] to advance to the next item
⚫
Press [▲] / [▼] to adjust the value
⚫
Press [blank] key to confirm and exit
Clear Wi-Fi Configuration (P19):
When set to yes, the SSID and Password stored
in the thermostat will be cleared
Clear Parameter setting (IP20):
When set to yes, all Internal parameter settings
will be restored to default value in next power on
i.e. power-cycle needed to complete the clearing.
Defrost
When the room temperature is below 5 oC / 41
oF, output will turn On at Heat mode or output
will turn off at Cool mode.
”defrost indicator
appears on the screen.
Minimum off time
The minimum off time for Heat mode is 5
seconds and 4 minutes for Cool mode.