koban 0769004 Installation Download Page 2

 

 

 

 
 
 

LCD Electronic Thermostat 

Code: 0769004,   

Reference: KT4-LCD-NP 

                                     

   

Before Installation 
 

 

 

Turn off 0769004, all electronic source and electrical devices 
which will be connected before installation and maintenance. 

 

 

The installer must be a trained service personnel. 

Installation Location   

The thermostat should be mounted on an inner wall ~1.5m above the floor in a position 
where  it  is  readily  affected  by  changes  of  the  general  room  temperature  with  freely 
circulating air.   
 
Prevent direct exposure to sunlight, drip or splash.   
 
Do not place the unit at a location where air circulation is low, or where there are great 
temperature  changes  (e.g.  near  door).  Do  not  place  the  thermostat  near  heat  generating 
sources (e.g. radiators, hot air vents, TV or lights). 

 

Wiring the Terminal 

For 0769004, there are 3 wiring terminals at the back of the thermostat which are labeled 
as “NC”, “NO” and “L”. Connect L to Live and NO to Heater or Cooler. Where NC is a 
Normally Close Valve. 

 

Mounting 

1.

 

Ensure that the surface is level. 

2.

 

Place the cables at the hole near the terminal block. 

3.

 

Insert 2 pcs of wall anchors into the holes of the wall. 

4.

 

Fasten the thermostat with 2 pcs of long screws through the 2 mounting holes as 
shown in the below figures. 

 
 
 
 
 
 
 
 
 
 
 
 

Opening 

Pull out the battery drawer and then lightly press on the spots shown below in order to detach 
the front shell from its base. 
 

 
 
 
 
 
 
 
 
 
 
 

Start / Reset 

When the system is reset, all the LCD segments are ON and the measured temperature will be 
displayed  after  a  while.  Low  Battery  Check  will  be  done  at  startup.  when  battery  is  low, 

  will be displayed and please replace the battery. 

*If  there  are  any  display  or  functional  errors,  please  remove  the  batteries  for  about  30 
sec to reset the thermostat. 

Normal Display Mode 

1.

 

Temperature detection starts and LCD displays the room temperature. 

2.

 

Below 0°C / 32°F, 0769004 will display

 LO

.

 

3.

 

Above 40°C / 99°F, 0769004 will display

 HI

4.

 

Press 

<Up>

 /

 <Down>

 to adjust Heat / Cool setting temperature. 

5.

 

Press 

<Mode>

 to select Heat / Cool / Off Mode 

 

 

- By default, press 

<Mode> 

to switch from Off to Heat or vice versa   

 

 

- To switch to Cool Mode, press & hold 

<Mode>

 for 2 seconds

 

in Off Mode.   

- Cool Mode will then be activated.     

 

 

 

 

 

- Use the same method to change back to Heat Mode.     

6.

 

Defrost function will be activated with 

  displayed when temperature is below 

5°C / 40

F in either Heat or Off Mode in Heat / Off pair. Heater is on regardless of the 

setting temperature. 

 

 
Temperature Setting 

To adjust heat/ cool setting: 
1.

 

Press 

<Up>

 or 

<Down>

 keys to adjust Heat / Cool setting temperature in normal display 

mode.   

2.

 

Heat/ Cool setting temperature flashes. 

3.

 

In Heat Mode, only heat setting temperature can be adjusted. 

4.

 

In Cool Mode, only cool setting temperature can be adjusted. 

5.

 

In Off Mode, no setting temperature can be adjusted. 

6.

 

The operation will resume to normal display mode after no key is pressed for 10 sec. 

 

Function Setting 

1.

 

Press and hold <

Backlight

> and <

Down

> keys for 2 seconds. 

2.

 

LCD changes to the display of Function Setting selection. 

3.

 

Press 

<Up>

 /

 <Down>

 to adjust Function Type/ Setting. 

4.

 

Press 

< NEXT > 

to select Function Type/ Setting.   

5.

 

Press 

<ENT>

 to return to the normal display mode. 

 

 
 

Table of the Internal Setting: 

Function Type 

Setting 

HS  Span of Heater 

+/- 0.3

C / 0.5

F (by default) 

+/- 0.5

C / 1

dU  Temperature Display Unit 

C (by default) 

CS  Span of Cool 

+/- 0.3

C / 0.5

F (by default) 

+/- 0.5

C / 1

Cd 

Compressor/ Heater 
Minimum-Off Delay 

1

 

1 minute compressor off delay (by default)

 

2 minutes compressor off delay 

3 minutes compressor off delay 

4 minutes compressor off delay 

5 minutes compressor off delay 

* When function type is being selected, output “NO” will be turned off 
automatically and 0769004 will enter Off Mode. 

 
 

Replace Batteries

 

1.

 

Choose the right type of batteries and install them with proper polarity.   

2.

 

Do not mix old and new batteries. 

3.

 

Remove batteries if they are used up or the thermostat will not be in used for a 
period of time.   

4.

 

Use 1.5V/cell alkaline batteries 2 pieces. 

 

Maintenance 

Caution: Switch off all electric sources before maintenance. We recommend 
that the maintenance should be performed by a   
trained personnel. 

No heating / cooling control: 

Check  the  thermistor  sensor  performance  by  measuring  the  corresponding 
variable resistance under different temperatures, if it is in good condition, the 
LCD  value  will  change  accordingly,  if  not,  trace  the  control  circuit  or  the 
LCD  connection,  replace  the  thermistor  sensor  if  necessary.  If  there  is  a 
problem with the control circuit, replace the PCB if necessary. 

 

Specification 

1.

 

Temperature Measurement:   

0 ~ 40

C / 32 ~ 99

F   

2.

 

Accuracy:   

 

 

±0.5

C/ 1°F 

3.

 

Temperature Controllable Range:   

Heat/Cool Setting:                 

5 ~ 35

C / 40 ~ 95

4.

 

Resolution:   

 

 

0.1

C /0.5°F 

5.

 

Power Supply: 

 

2 x AAA alkaline batteries 

6.

 

Rating: 

 

   

 

230Vac ~ 50/ 60Hz, 5(1)A. 

7.

 

Terminals:                                   

2mm

2

 cable   

8.

 

Operating Temperature: 

 

0 ~ 50°C / 32 ~ 122°F   

9.

 

Storage Temperature: 

   

-5 ~ 50°C/ 23 ~ 122°F 

10.

 

Sensing Element: 

 

 

NTC thermistor 

11.

 

Degree of Protection: 

 

IP-20

 

                                                                                                                               

TEMPER ENERGY INTERNATIONAL S.L. 

Polígono industrial de Granda, nave 18 

33199 • Granda - Siero • Asturias 

Teléfono: (+34) 902 201 292 

Fax: (+34) 902 201 303 

Email: [email protected] 

www.grupotemper.com

                                                                         

  140826 

<

Up

> key 

<

Down

> key   

 

<

ENT

> key   

Function 
Type   
 

<

NEXT

> key   

 

Setting Value 
 

Reviews: