USE

APPLICATION ADVICE

 • Stationary use 6.
    - set the tool down on its rear in an

      upright position
    - make sure the surface is clean and dust

      free; polluted air damages the motor
    - make sure the air flow is directed away

      from you
    - secure the cord to prevent pulling down

      the tool
    - do not touch the air outlet/nozzle
    - make sure nothing drops into the air

      outlet/nozzle
    - carefully hold the tool with one hand

      while switching it off with the other

      hand, and then allow it to cool down

NOTES:

    - all application examples 

(except

      removing paint next to glass)

 can be

      performed without accessories; however,

 • Removing paint/lacquer 0
    - use a clean, sharp scraper
    - scrape firmly, when the paint softens
    - experiment to establish the length of

      time necessary to apply the heat for

      optimal results
    - scrape the softened paint immediately,

      or it will harden again
    - keep a 30° to 40° angle between the

      tool and the workpiece
    - remove paint and debris immediately

      from the scraper to prevent them from

      ignition
    - scrape with the grain of the wood,

      wherever possible
    - do not direct the hot air flow towards

      the same surface for too long
    - dispose of all paint debris safely
    - thoroughly clean the work area after

      completing the job

! be

 careful when removing layers of paint 

in old buildings; in the past the building 

may

 have been painted with paint

containing lead, which is highly poisonous

! exposure

 to even low levels of lead can 

cause serious brain and nervous system 

damage; young and unborn children are 

particularly vulnerable
!the

 lead-based paint must be removed by 

a professional without using a heat gun. 

Not use lead-based soldering wire

      using the appropriate accessory simplifies

      the work and significantly improves the

      quality of the results

! Mount

 an accessory only when the 

air 

outlet is cold, when the switch is in position

 

“0” and when the plug is disconnected

 • Constant heat control (overload

    protection) Protects heating element

    from damage when tool is overloaded

    without having to stop it and/or let it

    cool down for a period of time
    - when the temperature gets too high,

      the heating element switches itself off,

      while the motor continues to run and

      produces cold air
    - when the temperature has fallen down

      sufficiently (taking only a few seconds),

      the heating element will be switched

      on automatically (“HEAT CONTROL” is

      no longer displayed).

! allow the tool to cool down for at least 

30 minutes before storage.

 • Thawing out frozen water pipes ^
    - heat the frozen area evenly

! do

 no thaw out water pipes made of PVC

! water pipes are often difficult to

distinguish from gas pipes; heating gas pipes

is extremely dangerous – risk of explosion

 • Drying

! only

 dry with a low or medium temperature

setting and with an increased distance 

between the tool and the workpiece

    - drying of paint, varnish, gypsum,

      mortar and plaster
    - drying wet timber prior to filing
    - drying thickly applied filer or adhesive

      quickly
    - drying building joints before spraying

      insulation or sealant
    - drying joints and cracks in boat building
 • Cleaning/disinfecting
    - disinfecting rabbit hutches, dovecotes,

      etc. 

(remove your pet first)

    - combatting ant colonies
    - combatting woodworms and boring

      beetles 

(hold the tool at an adequate

      distance from the wood)

    - eliminating weeds

Summary of Contents for KN HG-1500

Page 1: ...KN 7402 10P Digital heat gun1 500 WATTS Pistola de calor digital KN HG 1500...

Page 2: ...utton for increasing temp 2 Button for decreasing temp 3 LCD screen TECHNICAL DATA Power Voltage frecuency Consumption KN HG 1500 1 500 Watts 120 volts 60 Hz 12 5 A Adjustable temp Air flow volume Cor...

Page 3: ...all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future referenc...

Page 4: ...ple under the age of 16 years This tool is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have...

Page 5: ...ff the tool by pushing switch in position 0 Temperature setting set desired target temperature by pressing button 1 briefly do not suspend the tool by the cord Never use the tool in conjunction with c...

Page 6: ...lead based paint must be removed by a professional without using a heat gun Not use lead based soldering wire using the appropriate accessory simplifies the work and significantly improves the qualit...

Page 7: ...kaging together with household waste material If the tool should fail despite the care taken in manufacturing and testing procedures repair should be carried out by an authorized service center send t...

Page 8: ...Digital display 1 17 Cover 1 18 Rubber pad on cover 6 19 Inductor 1 20 Switch push button 1 21 Rubber pad on housing 1 22 Switch circuit board 1 23 Cable 1 24 Cable Sleeve 1 25 Screw ST4x14 1 26 Cable...

Page 9: ...EXPLOSIVE DIAGRAM KN HG 1500 Digital heat gun1 500 WATTS Pistola de calor digital...

Page 10: ...Bot n para aumentar temp 2 Bot n para disminu r temp 3 Pantalla LCD INFO TECNICA Potencia Voltaje frecuencia Consumo KN HG 1500 1 500 Watts 120 volts 60 Hz 12 5 A Temperatura ajust Vol de flujo de air...

Page 11: ...orporal con superficies conectadas a tierra como tuber as radiadores estufas y refrigeradores Existe un mayor riesgo de descarga el ctrica si su cuerpo tiene contacto con tierra c No exponga las herra...

Page 12: ...ser reparada c Desconecte la clavija de la fuente de alimentaci n antes de realizar ajustes cambiar accesorios o almacenar herramientas el ctricas Estas medidas de seguridad preventivas reducen el rie...

Page 13: ...de un interruptor de corriente de falla FI con una corriente de activaci n de 30 mA como m ximo y s lo use un cable de extensi n que est destinado para uso en exteriores y equipado con acoplamiento so...

Page 14: ...bre su parte posterior en posici n vertical aseg rese que la superficie est limpia y libre de polvo el aire contaminado da a al motor aseg rese que el flujo de aire sea dirigido lejos de usted asegure...

Page 15: ...as el calentamiento de tuber as de gas es extremadamente peligroso riesgo de explosi n Secado Solamente seque con un ajuste bajo o medio de temperatura e incrementando la distancia entre la herramient...

Page 16: ...talla digital 1 17 Cubierta 1 18 Pata de hule de cubierta 6 D e s c r i p c i n No part LISTA DE PARTES D e s c r i p c i n No part 19 Inductor 1 20 Bot n pulsador de Interruptor 1 21 Pata de hule de...

Page 17: ...DIAGRAMA DE PARTES KN HG 1500 Digital heat gun1 500 WATTS Pistola de calor digital...

Page 18: ...NOTES...

Page 19: ...NOTAS...

Page 20: ...www knova com mx...

Reviews: