background image

LED status Suitable Voltage 

Range

*24V~90V AC *90V~ 1000V AC

Green

24V ~ 90V AC

(KN 8065-E only)

Slow LED sensing

signal and buzzer

Fast LED sensing

signal and buzzer

Red

90V ~ 1000V AC No illumination,

no sound

Fast LED sensing

signal and buzzer

* Voltage ratings above should be taken for reference only, actual

   voltage range also depends on environmental factors such as

   AC noise and other electromagnetic interferences
5. Auto power off

    The detector will auto power off when it is not used for 5 minutes.

WARNING

         Do not mix old and new

batteries. Do not mix alkaline,

standard (carbon-zinc), or

rechargeable (ni-cad, ni-mh,

etc) batteries.

3. AC voltage detection

    Place the sensor head near the test object or the power socket

    with AC voltage. When AC voltage is detected, the red LED in the

    tip and buzzer will be on.

    In vibration mode, when strong signals are detected, there will also

    be vibration alarm (KN 8065-E only).

    Note: Please unplug other electrical devices on the socket

    before detection.

4. Detection range selection

    a) When the detector is on, the default mode is high voltage mode,

        with detection range of 90-1000V. The red indicator light on the

        panel will light up.
    b) Short press the power button once. The red indicator light will  

        switch to green, and the device will switch to low voltage mode,

        with range of 24-1000V. In low voltage mode, the detector is  

        more sensitive to electrical interference/noise. Please only use

        low voltage mode during weak electrical field environment.

        (KN 8065-E only)
        

Note: In the magnetic field detection mode, voltage cannot be

        detected at the same time.

6. Turning off the detector manually

    Short press the power button to turn off the detector (KN 8065-S

    only). Long press the power button for 2 seconds to turn off the 

    detector (KN 8065-S only).

8. Low battery indication

    When the battery voltage is lower than 2.4V, the detector will

    automatically shut down.

Battery Replacement

KN 8065-S:

1. Hold the detector with one hand,

    use your thumb of the other hand

    to press down on the battery

    compartment latch, and pull

    the end of the detector.
2. Pull out the end of the detector

    along the direction shown at

    right pictures and

    replace the batteries.

KN 8065-E:
1. Unscrew the battery cap

    counterclockwise as shown at

    right picture, and then replace

    the batteries according to the

    polarity indication.
2. Tighten the battery cap

    clockwise and the buzzer

    will beep twice to indicate

    the completion of

    the replacement.

VOLTAGE TESTER / LÁPIZ DETECTOR DE VOLTAJE

10. When using the detector, please only hold up to the line before

      the translucent sensing part and not over.

11. Comply with local and national safety regulations and equirements.

12. The detector will not detect any voltage if:

      • The wire is shielded

      • The operator is not connected with the ground or isolated from

         an effective ground

      • The voltage is DC

13. The detector may not detect any voltage if:

      • The operator does not hold the detector

      • The operator is wearing gloves

      • The wire under test is partially buried or in a grounded metal conduit

      • The magnetic field generated by the voltage source is blocked,

         suppressed or interfered with

      • The frequency of the voltage being detected is not a perfect

         sine wave and may be distorted by harmonics

      • The detector is used outside of the operating specifications

         (see Technical Specifications for details)

Protected throughout by Double insulation or

Reinforced insulation
Alternating current
A Caution, possibility of electric shock
A Warning! Refer to the manual
It is applicable to test and measuring circuits connected at

the source of the building’s low-voltage MAINS installation.

Electrical Symbols

Panel Description

1

  NCV sensor head 

2

  Flashlight lighting

3

  Sensing signal LED

4

  Mode status

    indicator light

5

  Power button

6

  Flashlight button

7

  Pocket clip

8

  End of the detector (KN 8065-S)

    Battery cap (KN 8065-E)

KN 8065-S

KN 8065-E

Operating Instructions

1. Turning on the detector

    Short press the power button. The buzzer will beep twice and

    the red indicator light on the panel will light up, indicating that

    the detector is on and ready for use. The default AC voltage

    detection range is 90-1000V.

KN 8065-E only:

    Long press (>1.5s) the power button. The detector will be on and

    vibrate. The vibration alarm will also occur when a strong signal is

    detected (only acousto-optic alarm for weak signals). To turn off 

    the vibration, power off the detector and then restart it by short

    pressing the power button.

2. Turning on/off the flashlight

    Flashlight on/off: Short press the flashlight button to turn on/off

    the flashlight.

    The flashlight will automatically turn off when the detector is not

    used for 5 minutes.