background image

Measurement Operation

5

• The LCD displays 

OL

 indicating open-circuit for

   the tested resistor or the resistor value is higher

   than the maximum range of the meter.
• When resistance measurement has been

   completed, disconnect the connection between

   the testing leads and the circuit under test, and

   remove the testing leads away from the input

   terminals of the meter.

D. Testing for Continuity 

(See figure 5)

figure 5

Select

          To avoid damages to the Meter or to the 

devices under test, disconnect circuit power and 

discharge all the high-voltage capacitors before 

testing for continuity..
To avoid harm to yourself, do not input higher than 

DC 60V or AC 30V voltages.
To test for continuity, connect the Meter as below:
1. Insert the red test lead into the 

Ω

 terminal and

    the black test lead into the COM terminal.
2. Set the rotary switch to       and press BLUE

    button to select measurement mode.
3. The buzzer sounds continuously if the resistor to

    be tested is <10

Ω

. The buzzer does not sound

    if the resistor to be tested is >35

Ω

Note

• Open circuit voltage is around 0.45V
• When continuity testing has been completed,

   disconnect the connection between the testing

   leads and the circuit under test, and remove the

   testing leads away from the input terminals of 

   the Meter.

WARNING

E. Testing Diodes 

(See figure 6)

          To avoid possible damage to the meter and 

to the divice under test disconnect circuit power 

and discharge all high-voltage capacitors before 

testing diodes.
To avoid harm to yourself, do not input higher than 

DC 60V or AC 30V voltages.

1. Insert the red test lead into the 

Ω

 terminal and

    the black test lead into the 

COM

 terminal.

2. Set the rotary switch to        and press BLUE

    botton to select        measurement mode.
3. For forward voltage drop readings on any

   semiconductor component, place the red test

   lead on the components anode and place the

   black test lead on the components cathode.

   The measured value shows on the display.

Note

• In a circuit, a good diode should still produce a

   forward voltage drop reading of 0.5V to 0.8V;

   however, the reverse voltage drop reading can

   vary depending on the resistance of other

   pathways between the probe tips.
• Connect the test leads to the proper terminals as

   said above to avoid error display. The LCD will

   display 

OL

 indicating diode being tested is open

   or polarity is reversed. The unit of diode is Volt (V),

   displaying the forward voltage drop readings.
• When diode testing has been completed,

   disconnect the connection between the testing

   leads and the circuit under test, and remove the

   testing leads away from the input terminals of 

   the Meter.

WARNING

figure 6

Select

F. Capacitance Measurement 

(See figure 7)

figure 7

Select

Summary of Contents for KN 8058

Page 1: ...KN 8058 Digital professional multimeter Mult metro digital profesional...

Page 2: ...lectrical symbols used on the meter and in this operating manual are explained on page 2 Rules For Safe Operation Digital multimeter KN 8058 is an auto ranging multimeter the enclosure structure desig...

Page 3: ...replacement parts The internal circuit of the meter shall not be altered at will to avoid damage of the meter and any accident Soft cloth and mild detergent should be used to clean the surface of the...

Page 4: ...nt Operation A DC AC Voltage Measurement See figure 2 B DC AC Current Measurement See figure 3 figure 2 Select To avoid harms to you or damages to the meter from electric shock please do not attempt t...

Page 5: ...Measuring Resistance See figure 4 Select figure 4 To avoid damages to the Meter or to the devices under test disconnect circuit power and discharge all the high voltage capacitors before measuring re...

Page 6: ...put terminals of the Meter WARNING E Testing Diodes See figure 6 To avoid possible damage to the meter and to the divice under test disconnect circuit power and discharge all high voltage capacitors b...

Page 7: ...en completed disconnect all the connection between multi purpose socket capacitor and the meter To measure frequency connect the meter as follows 1 Insert the red test lead into the COM terminal 2 Set...

Page 8: ...to Overload indication Display OL Battery Deficiency Display Press RANGE to enter the manual ranging mode the Meter beeps Press RANGE to step through the ranges available for the selected function the...

Page 9: ...inuous measurement less than 10 seconds at an interval more than 15 minutes Range 400 A 4000 A 40mA 400mA 4A 10A Range 400 A 4000 A 40mA 400mA 4A 10A Resolution 0 1 A 01 A 0 01mA 0 1mA 0 001A 0 01A Re...

Page 10: ...e the battery from the battery compartment 4 Replace the battery with a new 9V battery NEDA1604 6F22 or 006P 5 Rejoin the tilt stand battery compartment and case bottom and reinstall the screw To test...

Page 11: ...ucciones se explican en la p gina 11 Reglas de seguridad El mult metro digital KN 8058 es un mult metro con ajuste autom tico El dise o de la estructura de la carcasa ha adoptado la t cnica avanzada d...

Page 12: ...ticas El circuito interno del mult metro no debe modificarse a voluntad para evitar da os al mult metro y accidentes Debe utilizarse un pa o y detergente suave para limpiar la superficie del mult metr...

Page 13: ...tensi n de CD CA ver Figura 2 B Medici n de corriente de CD CA ver Figura 3 figura 2 Selector Para evitar da os personales o da os en el mult metro como consecuencia de descargas el ctricas por favor...

Page 14: ...r figura 4 Para evitar da os en el mult metro o en los dispositivos sometidos a prueba desconecte la alimentaci n del circuito y descargue todos los capacitores de alto voltaje antes de medir la resis...

Page 15: ...a os posibles en el mult metro y en el dispositivo sometido a prueba desconecte la alimentaci n del circuito y descargue todos los capacitores de alto voltaje antes de probar los diodos Para evitar da...

Page 16: ...conexiones del multifunci n el capacitor y el mult metro Para medir la frecuencia conecte el mult metro como se indica a continuaci n 1 Inserte la punta de prueba roja en la terminal Hz y la punta de...

Page 17: ...m xima 4000 frecuencia 9999 gr fico de barras anal gico de 41 segmentos Velocidad de medici n Se actualiza 2 3 veces segundo Rango Autom tico o manual Polaridad de pantalla Auto Indicaci n de sobreca...

Page 18: ...400mA 4A 10A Rango 400 A 4000 A 40mA 400mA 4A 10A Resoluci n 0 1 A 01 A 0 01mA 0 1mA 0 001A 0 01A Resoluci n 0 1 A 1 A 0 01mA 0 1mA 0 001A 0 01A Precisi n 1 0 2 1 2 3 1 5 3 Precisi n 45Hz 400Hz 1 2 5...

Page 19: ...a del compartimento de la bater a 4 Reemplace la bater a con una bater a nueva de 9 V NEDA1604 6F22 o 006P 5 Vuelva a unir el soporte de inclinaci n el compartimiento de la bater a y la parte de la ca...

Page 20: ...www knova com mx...

Reviews: