Location 

 
PU901 should be positioned so that the user can easily blow straight into the propeller.  
The push contact can be mounted on e.g. a gooseneck, contact your retailer for more information. 

Service 

 
When the user blows hard enough on the propeller to activate PU901, it will flash a green light.  
The receiver will give an acknowledgement, after which PU901 will glow steady green, indicating 
that the transmission was successful. 
If the transmission fails, PU901 repeats the transmission up to 2 times at 30 second intervals.  

Battery alarm 

 
If the battery in PU901 is low, the receiver will display "Low battery" when an alarm is received 
from PU901. 

Changing the battery 

 
The top and bottom of the PU901 can be unscrewed without tools. 

 

 
The battery is gently pressed out of the holder, 
for example with a cotton swab or a match. 

Never use a metal object. 

 
Carefully insert the new battery into the holder 
WITHOUT 
using tools, as this may short-circuit the battery. 
 

Use a CR2477 battery.   

IMP must be facing up.  

 
 
After replacing the battery, check PU901 as described under "Testing and commissioning". 
It takes about 1 minute after battery replacement before it can be activated. 
 
 

Main menu 

 
Use the head 

 

 

Summary of Contents for PU901

Page 1: ...KNOP Elektronik A S Fabriksvej 20 DK 7600 Struer knop knop dk knop dk 45 97840444 User manual PU901...

Page 2: ...840444 2 Table of contents Warnings and safety instructions 3 Intended use 4 Testing and commissioning 4 Check the coverage area 4 Location 5 Service 5 Battery alarm 5 Changing the battery 5 Main menu...

Page 3: ...attery in this product must compile with the relevant IEC safety standards for batteries Do not consume or eat the battery as there is a risk of chemical burns Keep new and used batteries away from ch...

Page 4: ...ioning After installation it is important that the user tests the product by blowing against the propeller Staff should receive an alarm to their alarm system receiver Refer to the instruction manual...

Page 5: ...nsmission fails PU901 repeats the transmission up to 2 times at 30 second intervals Battery alarm If the battery in PU901 is low the receiver will display Low battery when an alarm is received from PU...

Page 6: ...ed with a moist cloth or tissue The propeller can be gently pulled out with pliers or other tools and cleaned The product is then thoroughly tested If necessary the propeller can be replaced with a ne...

Page 7: ...ivations per day 2 Low battery alarm At approx 1 3 of residual capacity Surrounding environment Indoor use 90 non condensing Ambient temperature 0 C to 40 C Cabinet type White polyoxymethylene Cabinet...

Page 8: ...lectromagnetic compatibility Medical EN 62368 1 2020 Electrical safety EN 50581 2012 Hazardous substances The product must not be used if the packaging is damaged Medical Device Class 1 Manufacturer K...

Reviews: