3. If longer wires are required for the IR350, solid or stranded, 
shielded or unshielded with a minimum of 28-gauge for runs 
under 200’, 22-gauge for runs under 500’ and 20-gauge for 
runs up to 1000’. Wires can be looped from IR350 to IR350 or 
home run. Home wire runs normally offer more reliability and 
future flexibility. 
 
4. IR350s can be mixed and matched in larger systems with up 
to 10 Knoll infrared receivers. 
 
5. When connecting multiple Knoll infrared receivers to the 
IR155 detachable connector, make sure the infrared receivers 
are wired in parallel only. For a single IR350 connected to the 
IR155 infrared hub the red plug can be connected to the IR155 
red jack. If the wire length needed is longer or multiple infrared 
receivers are to be connected use the following procedure:  
Connect the infrared receiver(s) 

12V

GND

 and 

SIG

 terminals 

to the corresponding IR155 screw terminals. Prepare the wire 
leads to and from the IR receivers by stripping about ¼” of the 
insulation from each of the three leads. Twist the strands tightly 
together so that they do not stick out of the connector and 
cause a short circuit. Strictly observe polarity. 
 

IR350 wiring identification

 

 
 
 
 
 
 
 
 
 
 
 
 
 
6. Next, plug the single or dual emitter(s) into the Knoll 
connection block and position and attach the emitter output to 
the source components infrared receiver window. 
 

 
IR350 system typical layout 

 
 

 
 
 
7. Plug in the power supply. The Knoll PS1205 can power one to 
ten infrared receivers, one connection block and one to four 
single or dual emitters. 
 
8. The infrared system is usually left plugged in all the time (to 
an unswitched outlet) as it uses very little power. 
 
9. Test the infrared system to see if it is working properly. 
Bright sunlight and passive infrared security systems can lower 
the distance that remote controls can work with an IR350 
receiver.  
 
If you have any questions or concerns, please call and ask for 
infrared technical support at 1 800 566 5579. The help line is 
open from 7:30 a.m. to 4:00 p.m., Monday to Friday, Pacific 
time.

 

Receiver

CD

IR34A

IR34A

IR155

PS1205

12 V DC Power Supply

Dish

IR34A

171

Connection
    Block

12V
GND

SI G

 Controlled

Components

   INSIDE

   Cabinet

IR Receiver

Remote

Control

    IR

Receiver

Talkback

   LED

Wire with

printing

IR OUT Signal
GROUND
+12 VDC