3. Wires can be solid or stranded, shielded or unshielded with a 
minimum of 28-gauge for runs under 200’, 22-gauge for runs 

under 500’ and 20-gauge for runs up to 1000’. Wires can be 
looped from IR100 to IR100 or home run. Home runs normally 
offer more reliability and future flexibility. 
 

4. IR100s can be mixed and matched in larger systems with up 
to 10 infrared receivers, such as the IR210, IR220 or IR250. 
 
5. To wire the system together, connect the IR100 

12V

GND

 

and 

SIG

 terminals to the corresponding IR54 or IR55 terminal. 

Prepare the wire leads to and from the IR100 by stripping about 
¼” of the insulation from each of the three leads. Twist the 
strands tightly together so that they do not stick out of the 

connector and cause a short circuit. Strictly observe polarity. If 
you are connecting with the RJ45 connector you may need a 
RJ45 paralleling strip to parallel connect the wires from multiple 
IR receivers.  
 

6. Next, plug the single or dual emitters into the IR54 or IR55 
connection block. 
 

       IR100 system typical layout 

 

7. IF using the 

RJ45/cat5 connection only

 you can connect 

the positive of a second 5-20 VDC power supply to the pin 5 

labeled STAT. Connect that power supply ground to pin 3 
GROUND and plug the power supply into the switched outlet of 
the stereo receiver. This allows the IR100 Systems power LED 
to turn on and off when the stereo receiver is turned on and off.  

 
8. Now plug in the PS1205 for up to ten infrared receivers. 
 
9. The infrared system is usually left plugged in all the time (to 

an unswitched outlet) as it uses very little power. 
 
10. Test the infrared system to see if it is working properly. 
Bright sunlight and passive infrared security systems can lower 

the distance that remote controls can work with an IR100 
receiver. If you have any questions or concerns, please call and 
ask for infrared technical support at 1 800 566 5579. The help 
line is open from 7:30 a.m. to 5:00 p.m., Monday to Friday, 
Pacific time. 

 
 

 

RJ45 Wiring Diagram  IR100 front and back

 

RJ45

Receiver

CD

IR31A

IR34A

IR55

PS1202

12  V DC Power Supply

Dish

IR34A

171

Connection
    Block

Note:  IR100

’s are

wired in parallel

12 V

G ND

SI G

System

 power

on LED

    IR

Receiver

Talkback

   LED

RJ45

RJ 45

R J45