Knoll DIR22 Installation Instructions Download Page 2

Installation Tips 

 

1. Follow all local electrical & building code requirements. 

 

2. The DIR22 is mounted on the wall, cabinet door frame or other 
vertical mount. In order to work it requires a PS1202 (200 mA) or 

PS1205 (500 mA) 12 VDC unregulated power supply, IR31 (single) or 

IR34 (dual) emitters and one of the following: DIR54 (decora inwall 
style, 4 output), DIR55 (tabletop style, 4 output) or DIR58 (wall mount 

or SMC style, 8 output) connection block. 

 

3. Wires can be solid or stranded, shielded or unshielded with a 
minimum of 28 gauge for runs under 200’, 22 gauge for runs under 

500’ and 20 gauge for runs up to 1000’. Wires can be looped from 

DIR22 to DIR22 or home run. Home runs generally offer more 
reliability and future flexibility. 

 

4. DIR22’s can be mixed and matched in larger systems with up to 10 
DIR infrared receivers, such as the Knoll DIR21 or DIR10. 

 

5. When using a DIR connection block, connect the DIR22 +12vdc, 

GND and SIG terminals to the corresponding DIR55 or other Knoll 
digital connection block  terminal. Prepare the wire leads to and from 

the DIR receiver by stripping about ¼” of the insulation from each of 

the 3 leads.  
 

Twist the strands tightly together so that they do not stick out of the 

connector and cause a short-circuit. 

Be sure to observe polarity

.  

 

6. Next plug in the single or dual emitters into the DIR connection 

block.  
 

7. Then plug in the PS1202 (for up to five receivers) or PS1205 for five 

to eleven receivers. 
 

8. The infrared system is usually left plugged in all the time (to an 

unswitched outlet) as it uses very little power. 

 
9. Test the digital infrared system to see if it is working properly. If it 

works only from a very close range or it does not work at all, first mark 

where the pot adjustment is on the DIR connection block blue color 
pot. This is so you can reset it to that starting point again. Try 

adjusting the pot on the connection block very slightly left and right as 

you are testing the receiver with the remote control. This may require 
two people. This should correct for the problem. If it still does not work 

properly, please call Knoll Systems and ask for infrared technical 

support at 1-800-566-5579. The help line is open from 7:30 AM to 

5:00 PM Monday to Friday Pacific time. 