Installation Tips 

 
1. Follow all local electrical & building code requirements. 

 
2. The DIR10P is usually shelf or tabletop mounted. In order to 

work it requires a PS1202 or equivilent 12 VDC unregulated 
power supply and a IR31 (single) or IR34 (dual) emitter. A 
connection block is not needed. 

 
3. The two conductor emitter wire can be extended up to 1000’. 

Wires can be solid or stranded, shielded or unshielded with a 
minimum of 28 gauge for runs under 200’, 22 gauge for runs 

under 500’ and 20 gauge for runs up to 1000’. 
 

4. Simply plug in the single or dual emitter into the 3.5 mm jack 
port. If you are going to extend the emitter wire, carefully 
observe polarity. 

 
5. Plug in the PS1202 power supply and the DIR10P should be 

ready to go.   
 

6. The infrared system is usually left plugged in all the time (to 
an unswitched outlet) as it uses very little power. 

 
 
 

 
 

 

 
 

 
 

7. Test the digital infrared system to see if it is working 
properly. If it works only from a very close range or it does not 

work at all, first mark where the pot adjustment is on the 
DIR10P blue color pot on the rear of the DIR10P. This is so you 

can reset it to that starting point again. Try adjusting the pot on 
the connection block very slightly left and right as you are 
testing the receiver with the remote control. This may require 

two people. This should correct for the problem. If it still does 
not work properly, please call Knoll Systems and ask for infrared 

technical support at 1-800-566-5579. The help line is open from 
7:30 a.m. to 5:00 p.m. Monday to Friday Pacific time. 