Knightsbridge LEDADP36 Series Installation & Maintenance Manual Download Page 2

These instructions should be read carefully and retained after installation by the end 
user for future reference and maintenance.
These instructions should be used to aid installation of the following products:
LEDADP36 / LEDADP36W

GENERAL INSTRUCTIONS

SAFETY

INSTALLATION

•  Installation of this product should only be carried out by a qualified electrician or 

competent person to the current IEE Wiring Regulations (BS7671) and Building 
Regulations

• Please isolate mains prior to installation/maintenance
•  Check the total load on the circuit (including when this luminaire is fitted) does not 

exceed the rating of the circuit cable, fuse or circuit breaker

•  Please note the IP (Ingress of Protection) rating of this luminaire when deciding the 

location for installation

• This product is Class II double insulated
• Maximum LED load is 36W

• Find a suitable location which will provide adequate ventilation space around the product
•  Provide power to the required point of installation. Suitable IP rated junction boxes should be used where 

required

•  Connect the Live (brown), Neutral (blue) to the primary side of the driver  

(see Fig 1)

•  Connect the secondary side of the driver which is pre-wired to the LED load via a suitable female connector
• Switch on power supply and check for correct operation

Fig 1 

2