49
Specifi cations
Output data
Output, active
0/4 … 20 mA or 0 … 10 V, resp., or
–20 … 20 mA or –10 … 10 V, resp.
Output, passive
4 … 20 mA
Max. load (current)
active ≤ 12 V (600 Ω at 20 mA)
passive 12 ... 26
Max. load (voltage)
≤ 10 mA (1 kΩ at 10 V)
Overload capacity with
externally applied voltage
± 30 V
Displacement
up to ±150 % as default
Overload range
Current output: > 22 mA (max. 26 mA)
Voltage output: < 15 V
Off set adjustment
±5 %
Residual ripple
< 10 mV rms
Voltage drop when mea-
suring the output current
at test jacks 3.1 and 3.3
max. 150 mV
Transmission behavior
Gain error
Input ≤ 1 V
≤ 0.1% meas.val.
Input > 1 V
≤ 0.2 % meas. val.
Off set
≤ 0.1 % input range (full scale)
Linear dynamic range
–5% to 105% of input span
Signaling of load error
Red LED on the front
Response time T
99
*
< 200 ms or < 200 μs, switchable
Cutoff frequency
10 Hz or 10 kHz, switchable
*) Time after change of input value until reaching an output value
of 99 % steady state