Connecting the Compressed-Air Supply
The Unical 9000(X) is operated with an external air pressure of (4)* … 10 bar.
Adjust the pressure regulator so that the operating pressure for the retractable
fitting is kept within 4 and 7 bar. The air must be condensate- and oil-free.
Maximum air consumption during probe activation is 300 liter/min.
The connector for the compressed air supply is located behind the filter / water
trap. It has a G 1/4” female thread and accepts tubes with an inside diameter of
6 mm (preferably flexible). We recommend using the ZU 0656 connection kit.
* Increased minimum pressure required in the case of high process pressure or
difficult process media
Connecting the Water Supply
The Unical 9000(X) is operated with a water pressure of 2 ... 6 bar.
Water: filtered 100 µm, temperature 5 … 65 °C.
The connector for the water supply has a 1/4” female thread and 3/4” male
thread (with coupling nut) for preferably flexible tube, 1/2”.
As delivered, the connector is labeled ”Wasser/Water”.
We recommend using the ZU 0656 connection kit to protect against water
hammer. We also recommend using the RV01 check valve.
8.3 Media Supply to Unical 9000(X)
Compressed Air, Water, Purge Air, Auxiliary Media
!
CAUTION
Pneumatic
If water has entered the pneumatic system, you must immediately take the
device out of service.
Please contact the technical service department.
NOTICE
Drinking Water Pipes
Observe the general requirements of protection devices to prevent pollution
of potable water (EN 1717) when drawing water from drinking water pipes.
We recommend installing a suitable check valve on the water supply to the
Unical to protect the drinking water from pollution.