Knick Protos MS 3400-160 Manual Download Page 1

Communication Module

Protos® MS 3400-160

Communication Unit 

for Memosens® Sensors

MEMO

SENS

www.knick.de

Latest Product Information: 

Summary of Contents for Protos MS 3400-160

Page 1: ...Communication Module Protos MS 3400 160 Communication Unit for Memosens Sensors MEMO SENS www knick de Latest Product Information ...

Page 2: ...curring within 3 years from delivery date shall be remedied free of charge at our plant carriage and insurance paid by sender Sensors fittings and accessories 1 year 2010 Subject to change without notice Return of Products under Warranty Please contact our Service Team before returning a defective device Ship the cleaned device to the address you have been given If the device has been in contact w...

Page 3: ......

Page 4: ...4 ...

Page 5: ......

Page 6: ...inal Plate MS 3400 160 Module 18 Memosens Cable 19 Parameter Setting Operating Levels 20 Administrator level 20 Operator level 20 Viewing level 20 Parameter Setting Locking a Function 21 Configuring the Measurement Display 22 Documenting Parameter Setting 24 ProgaLog 3000 Software Option for Configuration and Documentation 26 Module Configuration Operating Mode 30 Memosens PH Parameter Setting 31 ...

Page 7: ...mosens ORP Parameter Setting 57 ORP calbration adjustment 62 Temperature dependence measured against SHE 63 Maintenance 64 Sensor monitor 64 Temp probe adjustment 64 Diagnostics Functions 65 Message list 65 Logbook 65 Sensor monitor 66 Cal record 67 Memosens OXY Parameter Setting 69 Calibration Adjustment 73 Adjustment 74 Recommendations for calibration 75 Selecting a calibration method 76 Automat...

Page 8: ...alibration Adjustment 103 Adjustment 104 Temperature compensation 105 Selecting a calibration method 106 Sensor calibration 115 Memosens COND Maintenance 116 Sensor monitor 117 Cal record 118 CONDI Parameter Setting SE 670 Sensor 119 Concentration Table 125 Calibration Adjustment 127 Adjustment 128 Temperature compensation 129 Selecting a calibration method 130 Calibrating the sensors 139 CONDI Ma...

Page 9: ...ts 151 Relay Contacts Protective Wiring 152 Relay contacts usage 153 Relay Contacts Sensoface Messages 154 Rinse Contact 155 Icons in the measurement display 156 Limit Value Hysteresis Contact Type 156 OK1 OK2 Inputs Specify Level 157 Switching Parameter Sets via OK2 158 Select Parameter Set A B via OK2 Input 158 Signaling Active Parameter Set via Relay Contact 158 Specifications 159 Index 161 ...

Page 10: ...gnal from a pressure transmitter for pressure compensation of oxygen sensors A galvanically isolated switching input allows the connection of monitoring equipment such as a flow monitor ing system Current input OXY pressure transmitter or flow for ex Switching input e g flow monitoring 1 2 3 4 5 7 9 11 13 Shield Memosens sensor ...

Page 11: ...e production and processing of electronic documents for pharmaceutical development and production This results in requirements for measuring devices used for corresponding applications The following features ensure that the Protos 3400 modular process analysis system meets the demands of FDA 21 CFR Part 11 Electronic Signature Access to the device functions is regulated and limited by individually...

Page 12: ...ules FRONT BASE slots 1 3 using the arrow keys Device description Return 22 7 C 7 00 pH Operating panel Protos Module FRONT 3400 011 Hardware 1 1 Software 9 0 Serial number 08150815 BASE Module FRONT Query actual device module software When the analyzer is in measuring mode Press menu key open Diagnostics menu Device description Options Device description Return 22 7 C 7 00 pH Digital sensors Modu...

Page 13: ...ditional functions options Additional functions must be ordered separately They are supplied with a device specific TAN for function release 3 module slots for free combination of measuring and communication modules Measuring modules pH ORP Temp O2 Temp Noncontacting conductivity Temp Contacting conductivity Temp MS Memosens interface Additional functions Activation via device specific TAN SmartMe...

Page 14: ...properly seated and clean Green LED Voltage supply okay 5 self sealing cable glands M20 x 1 5 for entry of voltage supply and signal lines 2 softkeys with context sensitive functions User interface with plaintext menus as recom mended by NAMUR Menu texts can be switched to German English French Italian Swedish Portuguese or Spanish Intuitively acquirable menu logic based on Windows standards Contr...

Page 15: ...BASE Module 1 Module 2 Module 3 SYSTEM FRONT BASE Module 1 Module 2 Module 3 Message list Point of meas description Logbook Device description FRONT BASE Module 1 Module 2 Module 3 4 5 6 Legend 1 Pressing the menu key accesses menu selection 2 Pressing the meas key returns to measurement 3 Menu groups are selected using the arrow keys 4 Press enter to confirm enter passcode 5 Further menu items ar...

Page 16: ...xchange of parameter sets 5 parameter sets can be stored on the SmartMedia card 2 of them can be loaded simultaneously to the analyzer and be switched by remote control Parameter sets can be transmitted from one analyzer to the other Function expansions are possible with additional software modules which are released using transaction numbers TAN Software updates The circumferential sealing guaran...

Page 17: ... notice concerning SmartMedia card The SmartMedia card may be inserted or replaced with the power supply switched on Before removing a memory card you must close it in the main tenance menu When closing the device make sure that the sealing is properly seated and clean Module equipment Module identification Plug Play Up to 3 modules can be combined as desired Several input and communica tion modul...

Page 18: ...can be sticked to the inner side of the door This facilitates maintenance and service Terminal plate MS 3400 160 module Terminal assignments for Memosens or M12 cable Terminal Wire color Connection 1 Brown BN Power supply 2 Transparent Shield 3 Green GN RS485 A 4 Yellow YE RS485 B 5 White WH Power supply GND ...

Page 19: ...ransmitter Specifications Material PEEK Cable diameter 6 3 mm Cable 2x2 twisted wire pairs Length up to 100 m Ambient temperature 20 C 135 C Ingress protection IP 68 Model code Cable type Cable length Order number Memosens cable 3 m CA MS 003NAA 5 m CA MS 005NAA 10 m CA MS 010NAA 20 m CA MS 020NAA Other lengths available on request M12 cable 5 m CA M12 005NA 10 m CA M12 010NA 20 m CA M12 020NA ...

Page 20: ...ith the lock symbol The functions are released or blocked using the softkey Operator level Access to all functions which have been released at the Administrator level Blocked functions are displayed in gray and cannot be edited Fig Viewing level Display of all settings No editing possible Menu selection Return to meas 25 6 C 11 03 pH Select enter Lingua Parameter setting Return 25 6 C 11 03 pH Vie...