7.3 Material Evaluation
The P45000 transducers with their combustible materials meet the material requirements according to
EN 45545-2 when installed on the exterior of rail vehicles. These include underfloor and roof contain-
ers. In the interior of rail vehicles, the transducers must be mounted in closed and fireproof control
cabinets.
The combustible materials are shown in the following list. Listed components were evaluated accord-
ing to their fire characteristics and fulfill hazard level HL 3. Components not included on the list were
evaluated and grouped according to Grouping Rule 1.
The components on the PCB required for the function meet the primary requirements from section 4.1
of EN 45545-2 (see section 4.7).
Component descrip-
tion
Combustible mass
in g
Rule/requirement
Result
Hazard level
Variant P45***K2*0*
1)
Printed circuit board
26
EL9/R24
fulfilled
HL 3
Housing
109
EL10/R26
fulfilled
HL 3
Partition
22
EL10/R26
fulfilled
HL 3
Potting compound
175
GR1/none
Exterior
n/a
Base bolt
5
GR1/none
Exterior
n/a
Variant P45***K2*1*
1)
Printed circuit board
26
EL9/R24
fulfilled
HL 3
Housing
109
EL10/R26
fulfilled
HL 3
Partition
22
EL10/R26
fulfilled
HL 3
Cable
150
EL1A/R15
EL1B/R16
fulfilled
fulfilled
HL 3
HL 3
Potting compound
175
GR1/none
Exterior
n/a
Base bolt
5
GR1/none
Exterior
n/a
Cable support sleeves
4
GR1/none
Exterior
n/a
Legend for flammable materials list according to EN 45545-2
EL9
Listed component: Printed circuit board
EL10
Listed components: Electrotechnical and electronic low-voltage components
GR1
Grouping Rule 1
HL
Hazard level
n/a
Not applicable
R24, R26
Sets of requirements in accordance with Table 5 Material requirements
1)
The individual product type can be determined from the order description, indicated on the narrow side of the
product (device front), and the product key.