background image

 

 

 

 

 
 
 

KNF worldwide 

 
Benelux  

Netherlands 

KNF Verder B.V.  

Utrechtseweg 4a 
NL-3451 GG Vleuten 
Tel. 0031 (0)30 677 92 40 
Fax 0031 (0)30 677 92 47 
E-mail: 

[email protected]

 

www.knf-verder.nl

 

 

Benelux  

Belgium, Luxembourg  

KNF Verder N.V.  

Kontichsesteenweg 17 
B-2630 Aartselaar 
Tel. 0032 (0)3 8719624 
Fax 0032 (0)3 8719628 
E-mail: 

[email protected]

 

www.knf.be

 

 

China  

KNF Neuberger Trading  

(Shanghai) Co., Ltd 
No. 36 Lane 1000 
Zhang Heng Road 
Shanghai 201203, P.R. China 
Tel. 0086 (0)21 685 965 66 
Fax 0086 (0)21 339 006 26 
E-mail: 

[email protected]

 

www.knf.com.cn

 

 

Germany 

KNF Neuberger GmbH  

Alter Weg 3 D-79112 Freiburg 
Tel. 0049 (0)7664 5909-0 
Fax 0049 (0)7664 5909-99 
E-mail: 

[email protected]

 

www.knf.de

 

 

France, Morocco, 
Algeria 

KNF Neuberger  

4, Bld. d’Alsace Z.I. 
F-68128 Village-Neuf 
Tel. 0033 (0)389 70 35 00 
Fax 0033 (0)389 69 92 52 
E-mail: 

[email protected]

 

www.knf.fr

 

 

 
Great Britain  

KNF Neuberger U.K. Ltd.  

Avenue 2 
Station Lane 
Industrial Estate 
Witney Oxon OX28 4FA 
Tel. 0044 (0)1993 77 83 73 
Fax 0044 (0)1993 77 51 48 
E-mail: 

[email protected]

 

www.knf.co.uk

 

 

India  

KNF Pumps + Systems 
(India) Pvt. Ltd.  

RAJIV GANDHI INFOTECH PARK 
Phase 1 
Ganga Estate, Survey No. 152/2/2 
Above AXIS BANK 
Hinjewadi 
Pune 411 057 
Tel. 0091 (0)20 640 13 923 
       0091 (0)20 640 08 923 
Fax 0091 (0)20 229 33 923 
E-mail: 

[email protected]

 

www.knfpumps.in

 

 

Italy 

KNF ITALIA S.r.l.  

Via Flumendosa, 10 
I-20132 Milano 
Tel. 0039 02 27 20 38 60 
Fax 0039 02 27 20 38 48 
E-mail: 

[email protected]

 

www.knf.it

 

 

Japan  

KNF Japan Co.Ltd.  

Chichibu, Bldg. 7F 
1-8-6 Shinkawa, Chuo-ku, 
Tokyo, Japan 104-0033 
Tel. 0081 (0)3 3551-7931 
Fax 0081 (0)3 3551-7932 
E-mail: 

[email protected]

 

www.knf.co.jp

 

 

Korea  

KNF Neuberger Ltd.  

Woosan Bldg.RM#202, 
336-4, Hwikyung-Dong 
Dongdaemun-Ku., 
130-090, Seoul 
Tel. 0082 (0)2 959-0255/6 
Fax 0082 (0)2 959-0254 
E-mail: 

[email protected]

 

www.knfkorea.com

 

 

 
Sweden, Denmark, 
Finland, Norway 

KNF Neuberger AB  

Mejerivägen 4,  
P.O. Box  44060 
SE-10073 Stockholm 
Tel. 0046 (0) 87445113 
Fax 0046 (0) 87445117 
E-mail: 

[email protected]

 

www.knf.se

 

 

Switzerland 

Sales 

KNF Neuberger AG  

Stockenstrasse 6 
CH-8362 Bichelsee-Balterswil 
Tel. 0041 (0)71 973 993 0 
Fax 0041 (0)71 973 993 1 
E-mail: 

[email protected]

 

www.knf.ch

 

 

Taiwan  

KNF Neuberger Ltd.  

9-2 FL., No., 24, Lane 123, 
Section 6, 
Ming Chuan East Road 
Taipei City, Taiwan 
Tel. 00886-2-2794-1011 
Fax 00886-2-8792-1648 
E-mail: 

[email protected]

 

www.knftwn.com.tw

 

 

USA, Canada, South America  

KNF NEUBERGER, INC.  

Two Black Forest Road 
Trenton, New Jersey 
08691-1810 
Tel. 001 (609) 890 86 00 
Fax 001 (609) 890 83 23 
E-mail: 

[email protected]

 

www.knf.com/usa.htm

 

South America  
Direct Phone: 001 609 649 1010 
E-mail: 

[email protected]

 

 

KNF product centres 

 
Product centre for gas 
pumps:  

Germany 

KNF Neuberger GmbH  

Alter Weg 3 
D-79112 Freiburg 
Phone 0049(0)7664 5909-0 
Fax 0049(0)7664 5909-99 
E-mail: 

[email protected]

 

www.knf.de

 

 
Product centre for fluid 
pumps:  

Switzerland  

KNF FLODOS AG  

Wassermatte 2 
CH-6210 Sursee 
Phone 0041(0)41 925 00 25 
Fax 0041(0)41 925 00 35 
E-mail: 

[email protected]

 

www.knf-flodos.ch

 

 
Product centre for micro 
pumps:  

Switzerland 

KNF Micro AG  

Zelglimatte 1b 
CH-6260 Reiden 
Tel. 0041(0)62 787 88 88 
Fax 0041(0)62 787 88 99 
E-mail: 

[email protected]

 

www.knf-micro.ch

 

Summary of Contents for UN86AT.16I

Page 1: ...was produced for the serial pumps stated above With customer specified projects pump types starting with PU or MPU there could be differences in detail For customer specified projects please therefore take into account any agreed technical specifications as well as these instructions List of Contents Page 1 Description Operating Conditions 2 2 Safety 3 3 Installation 5 4 Operation 6 5 Servicing 8 ...

Page 2: ...umps must not be used in areas where there is a danger of explosion Before pumping a medium the compatibility of materials of pump head diaphragm and valves with the medium must be checked for pump materials see section 10 These pumps must not be used for liquids You will find suitable liquid pumps in our Product Program If your potential application lies outside the above limits discuss it with o...

Page 3: ... automatically after cooling down Take all care necessary to prevent this leading to a dangerous situation Specific safety instructions for the media being handled must be observed When using hot media the pneumatic pump suction and pressure lines heat up as does the pump head Do not touch these parts they could burn you Use only original KNF spare parts For the purposes of the Machinery Directive...

Page 4: ...and hot parts if existing has to be provided when mounting The pumps conform to the EC Directive 201 65 EU RoHS2 The pumps conform to the EC Directive 2004 108 EC concerning Electromagnetic Compatibility The following harmonized standards have been used DIN EN 55014 1 2 DIN EN 61000 3 2 3 DIN EN 60335 1 ...

Page 5: ...articular make sure that the electricity supply is isolated before trying to connect the pump Compare the supply data with the data on the motor plate The voltage must not vary by more than 6 and 10 from that shown on the type plate The earth ground wire must be connected to the motor In the electrical installation arrangements complying with EN 60335 1 must be made for disconnecting the pump moto...

Page 6: ...ecifications section 10 If necessary consider any external sources of energy such as radiation that may add heat to the medium In case of doubt consult the KNF customer service Before pumping a medium the compatibility if material of pump head diaphragm and valves with the medium must be checked for pump material see section 10 The pump must not start against pressure or vacuum When it is switched...

Page 7: ...ump will re start automatically after cooling down Take all care necessary to prevent this leading to a dangerous situation Diaphragm and valve plate are the only parts subject to wear Wear is usually indicated by a drastic reduction in the pneumatic performance When replacing parts proceed as described in section 5 Ambient conditions see section 1 3 ...

Page 8: ...cessary safety measures example the use of protective gloves 3 Ensure that the discarded parts and materials are safely and correctly disposed of After opening the pump head or replacing the diaphragm and valve plate the initial gas tightness is no longer guaranteed A leak test is able to verify that the original standard of gas tightness has been achieved Spare part Quantity Valve plate 1 Wave di...

Page 9: ...d f Final step Fig 3 Pump head exploded drawing Fig 2 UN86 16AT 16I Fig 4 Orientation of disk springs 5 Specification Pos Description 1 Carrier 2 Wave diaphragm 3 Intermediate plate 4 Head plate 5 Disk spring 6 Nut 7 Retainer plate 8 Diaphragm support 9 Connecting rod extension 10 O ring 11 Valve plate 12 Washer 13 Fan M Mark ...

Page 10: ...1 Release the retainer plate 7 by turning it anti clockwise with a pin wrench or a wrench for retainer plate While doing so hold the connecting rod extension 9 in place with holding tool Take care to ensure that the washer 12 does not slip under the diaphragm support 8 2 Remove wave diaphragm 2 3 Check that all parts are free from dirt and clean them if necessary see section 6 Cleaning 4 Slide a n...

Page 11: ...1 Place the head plate 4 on the intermediate plate 3 in the position indicated by the felt tip pen marking 2 Place disk springs 5 For position see fig 4 3 Put the nuts 6 in place and tighten them diagonally until each of them lies level on the top spring washer realign the pump head From when you start applying pressure on the disk springs tighten the nuts through an angle of 340 That is equivalen...

Page 12: ...n the system Diaphragm or valve plate is worn Section 5 Servicing Flow pressure or vacuum too low Compare the actual performance with the figures in section 10 or the data sheet There is pressure on the pressure side and at the same time vacuum or a pressure above atmospheric on the suction side The pump is not designed for this condition Liquid condensate has collected in the pump head Let the pu...

Page 13: ...media which were pumped and on pump cleaning Please fill out the corresponding KNF form and submit it together with the pump A sample statement for copying can be found in section 11 of these operating instructions 8 Replacement parts Spare part Order No Valve plate 006066 Wave diaphragm 012074 O Ring 052713 Disk spring 005205 Tab 3 Replacement parts 9 Accessoires Accessory Order No Wrench for ret...

Page 14: ...l min at atm pressure UN86AT 16I 1 5 290 6 UN86ST 16I 1 5 290 6 Tab 5 Pneumatic Data Liter at STP Pump type Material Pump head Wave diaphragm Valve plate UN86AT 16I Aluminium alloy PTFE PTFE UN86ST 16I Stainless steel PTFE PTFE Tab 6 Pump materials Pump type Thread size UN86AT 16I I 8 NPT UN86ST 16I I 8 NPT Tab 7 Size of pneumatic port threads ...

Page 15: ...ve an RMA number submit a completed Decontamination Declaration form to rma knf com The Decontamination Declaration form can obtained from our website or by contacting KNF Technical Services http www knf com pdfs decontamdec doc Phone 609 890 8600 Product return instructions will be provided when the RMA is issued KNF Neuberger Inc 2 Black Forest Rd Trenton NJ 08691 1810 Phone 609 890 8600 Fax 609...

Page 16: ...ibu Bldg 7F 1 8 6 Shinkawa Chuo ku Tokyo Japan 104 0033 Tel 0081 0 3 3551 7931 Fax 0081 0 3 3551 7932 E mail info knf co jp www knf co jp Korea KNF Neuberger Ltd Woosan Bldg RM 202 336 4 Hwikyung Dong Dongdaemun Ku 130 090 Seoul Tel 0082 0 2 959 0255 6 Fax 0082 0 2 959 0254 E mail knf knfkorea com www knfkorea com Sweden Denmark Finland Norway KNF Neuberger AB Mejerivägen 4 P O Box 44060 SE 10073 ...

Reviews: