7.  Operation 

  Only  operate  the  pumps  under  the  operating  parameters  and 

conditions described in Chapter 4, Technical data, and in Sec-
tion 2.3, Using the pump in a potentially explosive atmosphere. 

  Make sure that the pumps are being used properly (see Chap-

ter 2.1). 

  Avoid improper use of the pumps (see Chapter 2.2). 

  Observe the safety precautions (see Chapter 3). 

  The  pumps  are  components  that  are  intended  to  be  incorpo-

rated into another machine. Before putting them into service it 
must  be  established  that  the  machinery  or  systems  in  which 
they are installed meet the relevant regulations. 

 

CAUTION 

 Risk of burning 

The drive heats up. 

 

  Avoid contact with the pump drive 

  Avoid contact with flammable materials. 

 

 

Excessive  pressure  and  the  inherent  dangers  thereof  can  be 
prevented by placing a bypass line with a pressure relief valve 
between the pressure and suction side of the pump. For further 
information,  contact  your  KNF  technical  adviser  (Telephone 
number: see first page). 

 

 

WARNING 

 Risk  of  explosion  as  a  result  of  high  ambient  tem-

perature 

  Monitor  ambient  temperature  (heat  of  compres-

sion, motor heat). 

  Provide an adequate supply of cooling air. 

 

  If  the  pump  stops  running,  restore  the  system  to  normal  at-

mospheric pressure. 

Check the pump regularly for external damage or leaks. 

 

Duty cycle / short cycle operation 

KNF pumps are designed for continuous operation. 

 

If  the  pump  is  operated  with  short  cycles  in  your  application, 
please  contact  a  KNF  technical  adviser  for  further  information 

(Telephone number: see first page). 

 

Switching on the pump 

  In order to ensure that the pump starts every time, make sure 

that  counterpressure  is  reduced  to  an  acceptable  level  before 
start-up. This should also be done during operation after a brief 
power cut. 

Pump standstill 

Check the pump 

Short cycle operation 

Summary of Contents for NF 1.300 EX

Page 1: ...of the mechanical pump and electric drive motor parts the device has two rating plates Each rating plate describes only the part of the device to which it is applied An additional letter prefixing the...

Page 2: ...1 2 Symbols and markings Warning WARNING This symbol indicates a potential danger It also indicates the possible consequences of failure to observe the warning The signal word e g Warn ing indicates...

Page 3: ...m working correctly If this cannot be guaran teed a filter 100 m with sufficiently large filter area must be used upstream of the pump 2 2 Improper use For special modifications outside the standard t...

Page 4: ...r continuously for long periods or frequently Very high 2 Areas in which hazardous explosive atmospheres are likely to occur occasionally High 3 Areas in which it is unlikely that hazardous explosive...

Page 5: ...ethane Acetic anhydride Benzene Diesel fuel Aviation turbine fuel Heating oils n hexane Acetaldehyde IIB Town gas Ethylene Ethyl alcohol Hydrogen sulphide Ethyl ether IIC Hydrogen Acetylene Carbon dis...

Page 6: ...n Description bh Protection by Control of Ignition Source h Constructional safety kh Liquid encapsulation d Pressureproof enclosure e Increased safety i Intrinsic safety p Pressurisation m Encapsulati...

Page 7: ...edium observe the safety regula tions for handling such medium Always ensure adherence to all information stickers on the pumps such as flow direction arrows and rating plates and keep stickers in leg...

Page 8: ...t A risk analysis was carried out in accordance with EN 1127 1 Ignition sources If the pump compresses against the maximum permissible operat ing pressure the temperature of the head will not exceed t...

Page 9: ...his would be noticed at once because flow rate would fall considerably In the event of damage the loose steel component would be channelled by the pump housing Even in the event of a malfunction no sp...

Page 10: ...ab 8 1 according to DIN ISO 1629 and 1043 1 The pump type TT stands for Assembly Material1 Pump head PVDF Valve plate FFKM Diaphragm PTFE coated Resonating diaphragm PTFE Diaphragm 27 FFKM FKM Tab 91...

Page 11: ...ding on the version Other parameters Parameter Value Permissible ambient temperature range C 5 to 40 Permissible medium temperature range C 5 to 40 Permissible kinematic viscosity of medium cSt 150 Ta...

Page 12: ...medium to be transferred via the inlet valve 2 In the upward stroke the diaphragm pushes the medium out of the pump head via the outlet valve 1 The diaphragm hermetically seals off the working chamber...

Page 13: ...ee Chapter 3 6 1 Installation Before installation store the pump at the installation location to bring it up to ambient temperature Mounting dimensions see Fig 3 NF1 300 Ex NF1 300 27 Ex Fig 3 Mountin...

Page 14: ...nst touching parts which are energised live such as electrical connections or windings Take protective measures against touching moving parts e g fan Danger of damaging the pump during operation Take...

Page 15: ...ing plate matches the nominal values of the electrical power supply Voltage and fre quency values must comply with the mains data tolerance 5 the drive motor is protected against excessive heating by...

Page 16: ...he pump Connect individual conductors of the motor supply cable to the terminal bar Tighten the clamping pressure screw of the screwed cable gland to a torque of 2 5 Nm Carefully inspect the marked ea...

Page 17: ...he environment during pressure relief Make sure that the medium cannot combine with the pump s environment during pressure relief During pressure relief make sure that the medi um is captured in a sui...

Page 18: ...pressure and the inherent dangers thereof can be prevented by placing a bypass line with a pressure relief valve between the pressure and suction side of the pump For further information contact your...

Page 19: ...contact your KNF technical adviser Switching off the pump KNF recommends If transferring aggressive liquids the pump should be flushed thoroughly prior to switch off see Chapter 8 2 1 as this will hel...

Page 20: ...pending on the pressure in your system the recommended time interval will vary see table below Please contact your local KNF Company to discuss the best way of implementing this service Operating pres...

Page 21: ...lable blow off components Pump or drive disconnected from the mains and de energized The pump must be free of any hazardous substances Hoses must be disconnected from the pump head We recommend replac...

Page 22: ...the section that corresponds to the pump type you are using NF 1 300 version or NF 1 300 27 version Re connect the hoses to the pump head NF 1 300 version Insert the resonating diaphragm 6 in the conn...

Page 23: ...no washers for FT 7 Insert the four head screws 1 in the through holes of the pump head 8 Make sure that the flow direction of the pump head see direc tional arrow on the head plate 16 is the same as...

Page 24: ...p for overflow Switch on the pump and run until there are no air bubbles in the system Close the valve downstream of the pressure gauge and check the overflow pressure at the gauge Undo the hexagon nu...

Page 25: ...l lation Instructions for the drive motor Pump does not work Possible cause Fault remedy Pump not connected to mains power supply Connect pump to mains supply Power supply is not switched on Switch on...

Page 26: ...een hose and hose connections with clamps or clamping elements Particles in the pump Clean the pump head install suction side filter if required see Section 8 2 Viscosity of the liquid is too high Con...

Page 27: ...ered Start up time exceeded Check start up condi tions Tab 20 Fault cannot be rectified If you are unable to identify any of the above causes please send the pump to KNF customer service see address o...

Page 28: ...n condition that the customer provides certification of the transferred medium and the cleaning of the pump decontamination declaration In order to send a product back use the decontamination declarat...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...KNF worldwide Please find your local KNF partners at www knf com...

Reviews: