Installation and connection
Diaphragm pump N922S_E IP54
16
Translation of Original Operating and Installation Instruction, english, KNF 318667-318664 05/21
7.2 Aligning the compressor housing
Tool
Quantity
Tool/material
1
Allen key, 2 mm
1
Allen key, 4 mm
Tab.9
If damp gases are transferred with the pump, condensate may form
in the pump head during operation. This results in, among other
things, a reduction of the performance.
To ensure optimum suction capacity, it is possible to orient the
pump head downwards so that the condensate that forms can sim-
ply drain out of the pump head. For this purpose, the compressor
housing including pump head (depending on installation position)
can be rotated in increments of 90° and mounted.
1
Housing cover
2
Allen screws
3
Eccentric
4
Motor fastening screws
Fig.5 Removing the housing cover
1. Loosen the four Allen screws (
2
) of the housing cover (
1
) and remove
them.
WARNING
Risk of explosion from damage.
If the housing cover is bent or if the paint is dam-
aged, there is no risk of explosion.
à
Perform the work steps carefully and without
the use of force.
2. Remove the housing cover (
2
).
The eccentric crank drive (
3
) and the four motor fastening screws (
4
)
become visible.
3. Loosen and remove the four motor fastening screws (
4
).
Summary of Contents for N922SPE