Use
Diaphragm pump N026 EX
6
Translation of Original Operation and Installation Instruction, english, KNF 059217 11/19
2.3 Use in potentially explosive areas
In potentially explosive areas (zones), only operate pumps of the appropri-
ate device category and temperature class.
The pumps have the following explosion protection designation:
Designation
Description
Symbol for explosion-proof pumps
II
Device group (See Chapter
2/2G
Ex
Symbol indicates that the device complies with
one or more ignition protection types
H
Symbol for ignition protection type (See Chapter
II B + H2
T4
Temperature class (see Chapter
)
Gb
Equipment protection level (See Chapter
Equipment protection level for gas
Special operating conditions (See Chapter
Tab. 5
An ignition hazard assessment in accordance with standards DIN EN ISO
80079-36 and DIN EN ISO 80079-37 was performed for the pumps. The
protective goals were reached by applying ignition protection type con-
structional safety "c".
The explosion protection designation can also be found at the following lo-
cation:
§
Type plate of the pump
Motor The pump motor must have at least the same explosion protection as the
pump.