Diaphragm Pump N 035 E
Servicing
KNF N 035 E e 08/09 Translation of the original Operating and installation instructions
21
8. Servicing
8.1. Servicing Schedule
Component
Servicing interval
Pump
Regular inspection for external damage or
leaks
Diaphragm and
valve plates or reed
valves
Replace at the latest, when pump output
decreases
Silencer/filter (ac-
cessory)
Change if it is dirty
Tab. 7
8.2. Cleaning
When cleaning, make sure that no liquids enter the inside of
the housing.
8.2.1. Flushing Pump
When transferring aggressive media, flush the pump under atmos-
pheric conditions some minutes with air (or, if necessary for safety
reasons, with an inert gas) prior to switch-off to increase the ser-
vice life of the diaphragm.
8.2.2. Cleaning Pump
Only use solvents for cleaning if the head materials cannot be
attacked (check the resistance of the material!).
If compressed air is available, blow out the components.