Version 2018-14-CN
59
Technical Data are subject to change without notice!
Inductive power supply
RING COIL - Distance power head and pickup head
Data cable CAT. 7A S/FTP 4P AWG22 (= solid bare copper wire 0.64mm-diameter) recommend
or
Data cable CAT. 7 S/FTP 4P AWG23 (= solid bare copper wire 0.55mm-diameter)
IND-Data Pickup
Distance to coil
typical 5-50mm
In ideal case upto 100mm
IND-PWR Head
Distance to coil
5-30 mm
IND-Data Pickup
Distance to coil
+/-50mm
IND-Data Pickup
Distance to coil
+/-50mm
Solder pins for data coil and wire to
IND-TX 45MHz
Please use twisted wire
If you use longer wires >100mm, please use shied and twisted wire e.g. LAN
cable CAT 7 !
max. 1000mm recommend (only shielded!)
Solder pins for power coil and wire to
IND-PWR 6.5V
Please use twisted wire (must not shield!)
CUL 0.63 mm for IND-DATA
coil - 1 winding
CUL 0.63 mm for IND-PWR
coil - 5 winding
(Enamelled copper wire)