Version 2020-17
.3
Technical Data are subject to change without notice!
Page 39 (44)
Inductive transmission
(2500kbit) with MTP
-NT-
IND
-TX-RX with
45MHz carrier!
With 45MHz
carrier is only
1x
winding
necessary!
Attach for electromagnetic insulation “Ferrite Tape”
2 x one
layer around the shaft.
Make transmitting coil with
1x winding
and twisted the
end of wire. Use CUL 0.63, 0.75 or 1.00mm wire
(CUL = Enameled copper wire)
Fix it with 3 layers mounting tape
Extend the CUL wire flexible 0.14-0.25mm wire
(to decouple the inflexible 1mm wire!,
at 0.75 not necessary)
Twist the flexible wire and solder it on the MTP-NT IND-
Tx (isolate all solder points with shrink tubing)
Strip the isolation from the end
of the wire with a skinning tool or
heat up your soldering iron over
450°C to burn off the insulation
from the wire!