Ventilation Conditions
- In rooms with a volume below 5 m
3
, continuous free air ventilation of 500
cm
2
is required.
- For rooms with a volume between 5 m
3
to 10 m
3
, continuous free air
ventilation of 100 cm
2
is required. If the room has a door opening directly
outdoors, continuous ventilation is not required.
- Continuous ventilation is not required for rooms with over 10 m
3
volume.
Not: Irrelevant with the room size, all the rooms that the appliance is
installed in must have an opening window or direct access to outdoors air
through equivalent means.
- The conditions specified above allow the use of a gas oven and grill, but if
there are other gas appliances in the same room, consult a competent
engineer.