Operating instruction Spring closing unit INTEC 40KS
Page
1
of
3
Valid from 04/2018
Operating instruction for
KLINGER SCHÖNEBERG Spring Closing Unit,
Type INTEC 40KS
Contents
1
Validity .......................................................................................................
........................ 1
2
Predefined application and maximum load ................................................
........................ 1
3
Safety .........................................................................................................
........................ 1
4
Installation ..................................................................................................
........................ 2
5
Specifications..............................................................................................
........................ 2
6
Setting the spring-force ..............................................................................
........................ 2
7
Marking ......................................................................................................
........................ 3
1 Validity
This operating instruction is valid for the INTEC 40KS spring closing unit.
2 Predefined application and maximum load
The spring closing unit INTEC 40KS is a user friendly, robust and easy to mounted safety device for all
quarter turn valves up to the torque requirement
indicated under point 5 “specifications”. The valve is
actuated by the hand lever. Upon release of the hand lever the valve will be opened, by the spring-force,
back to the default safe position (open position).
3 Safety
The non-compliance of these safety notes leads to the loss of any claim for damages.
Safety notes:
Beside our safety notes, national rules and regulations regarding the accident prevention, working-,
operating and safety rules of the operator must be kept.
The valve should be opened with manual force in an even manner and not too quickly, since
movements that are too quick or jerky may cause a surge of medium (hydraulic shock) to overload
the system.