KLING & FREITAG PASSIO SUB 12 Operating Instructions Manual Download Page 7

Operating Instructions

K&F PASSIO SUB 12

KLING & FREITAG GMBH © 2016

Version 1.3

Page 7 of 19

3.

Safety Instructions

3.1

Notes for Mounting the Speakers

Warning

Mount the speakers securely. To avoid injury or damage, always be sure to mount the
speakers securely so that they do not fall.

Please note that speakers can move as a result of vibrations. To prevent them from falling
from their mounted position, they must be secured properly.

Run the cables in a way that nobody can trip over them.

3.2

Instructions for Speaker Stacking

Warning

Falling speakers pose the threat of fatal injuries to people near them!

Be sure to follow the relevant national specifications, norms, and safety regulations.

Always make sure that a sufficient safety level is still given, even when outside forces have
an additional impact on the stacked speakers. Before setup, carefully ascertain if there are
any possible outside forces that could result in the array falling over. (Slant of the ground /
the bearing capacity of the ground / wind / person or vehicle impact, etc.). A technical expert
who is responsible for the setup must evaluate and determine necessary measures (including
calculating the statics). If necessary, obtain expert proof of stability.

Stacked systems may not fall over even if they are inclined by 15° in each direction. If this
requirement is not fulfilled, then it is necessary to take steps to achieve compliance. Possible
measures include strapping it to an appropriate base structure or fastening it using safety
straps. A planned tilt of the loudspeakers ist not permissible. In calculations, the tilted setup
serves the purpose of levelling out unevenness.

With the set-up systems for which you cannot verify the structural safety without safeguards,
you must secure them to prevent sliding or tipping in order to provide proof of this safety. To
secure the system from tipping over, use water tanks or floor bolts. Other possible measures
include strapping it to a suitable substructure or tying it using safety straps.

For outdoor and trade fair venues in which wind loads must be considered, additional proof
of stability is necessary.

Make sure that the stacking feet of subwoofers stacked on top of one another are securely
positioned in the grooves of the lower speaker.

If you place a top speaker on a PASSIO SUB 12 you must always strap the speakers to one
another and secure them from falling over.

3.3

Preventing Hearing Damage

Caution

Keep your distance from operating speakers. This equipment is capable of delivering sound
pressure levels in excess of 90 dB SPL, which may cause permanent hearing damage.

3.4

Protecting the Speakers / Operating Safety

PASSIO SUB 12 speakers may only be used in combination with a K&F SystemAmp/
SystemRack.

In general, audio signals must not be overdriven. This may be caused by mixing consoles,
equalizers, effect equipment, etc. and should be indicated on this equipment. When a power
amplifier is overloaded at the output (clipping), then the amplifier activates a clipping
warning signal. In any case, the signal must be reduced as soon as it sounds unnaturally
distorted.

Summary of Contents for PASSIO SUB 12

Page 1: ...n Please Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Operating Instructions Translation of the original instru...

Page 2: ......

Page 3: ...Hearing Damage 7 3 4 Protecting the Speakers Operating Safety 7 4 Fuse in the PASSIO SUB 12 9 4 1 Replacing the Fuses 9 5 Configuration and Connecting Diagram 10 5 1 PASSIO SUB 12 combined with other...

Page 4: ...s or damage Tip This icon marks information provided for simplified use of the described products 1 2 About these operating instructions KLING FREITAG GMBH All rights reserved All specifications regar...

Page 5: ...oofer PASSIO SUB 12 1x Operating Instructions 2 2 System Requirements Lab gruppen IPD 2400 or K F PLM 20k44 SystemAmp ProRental K F PLM 12k44 SystemAmp ProRental with K F Connector Panel CP Anschlussf...

Page 6: ...ing grooves on top of the enclosure for stackings of identical enclosures 2 2x handle 3 Threaded stand flange with M20 threads for use with distance rod 4 Front grille 5 2x SpeakOn connector 4 pin NLT...

Page 7: ...propriate base structure or fastening it using safety straps A planned tilt of the loudspeakers ist not permissible In calculations the tilted setup serves the purpose of levelling out unevenness With...

Page 8: ...which occur when the amplifier is on while equipment is being connected disconnected or switched on Do not install devices in any of the following places where the devices are permanently exposed to d...

Page 9: ...d as the fuse just prevents consequential damage resulting from a short circuit of the chassis A replacement of the chassis is therefore unavoidable Required tools 1 3 mm Allen key for loosening the f...

Page 10: ...rs in 2 Channel Mode The PASSIO SUB 12 can only be combined in 2 channel mode with all K F top speakers when using a K F systemamp or systemrack To do so select the desired LS blocks for the top speak...

Page 11: ...g tops PASSIO SUB 12 combined with Selected LSBlock Controller CD 44 Filename K F PASSIO 2xPassio PSub12 K F 2x Passio Passio Sub 12 K F GRAVIS 8 2xGra8W PSub12 K F 2x Gravis 8 W Passio Sub 12 K F GRA...

Page 12: ...16 Version 1 3 Page 12 of 19 PASSIO SUB 12 PASSIO IPD2400 EU LS Block To the next IPD2400 EU IPD2400 EU Tip Depending on the top used you must make allowances in 1 channel operations for more or less...

Page 13: ...tions check the speaker for signs of wear at regular intervals When performing those checks particularly look for deformations cracks dents damage to threads and corrosion Also check slings and lifts...

Page 14: ...innen und au en bel ftet geringste Verzerrungen durch Demodulationsring Speakers channel 2 with Lab gruppen IPD 2400 and K F TOPAS 3 with K F SystemRack K F PLM and K F D Serie Connection 1 1 2 x spea...

Page 15: ...Operating Instructions K F PASSIO SUB 12 KLING FREITAG GMBH 2016 Version 1 3 Page 15 of 19 9 Measuring Diagrams Frequency response Frequency response with system controller 10 Dimensions PASSIO SUB 12...

Page 16: ...s subject to the WEEE that are distributed in Germany with an icon showing a crossed out garbage can with a white bar below it The icon indicates that the equipment was distributed on or after 24 Marc...

Page 17: ...ns K F PASSIO SUB 12 KLING FREITAG GMBH 2016 Version 1 3 Page 17 of 19 11 3 All Other Countries Contact your retailer or the local authorities for information on the regulations applicable in any coun...

Page 18: ...5 SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage use...

Page 19: ...Operating Instructions K F PASSIO SUB 12 KLING FREITAG GMBH 2016 Version 1 3 Page 19 of 19 Managing Director CEO...

Reviews: