Klimosz Combi B 15 Technical Data Manual Download Page 5

Operation and installation manual part 2.

  

2015.10.08 

 

 

Fuel parameters: 

 

calorific value 

kg

MJ

Q

r

i

/

15

>

 

ash content 

%

12

<

r

A

 

moisture content coal pellets 

%

15

<

r

W

,    

                                     wood 

%

20

<

r

W

; 

 

 

 

volatile matter content 

%

28

>

r

V

 

ash fusion point 

C

t

o

A

1200

>

 

caking properties 

20

<

RI

 (max 30); 

 

low swelling 

 

 
ATTENTION!!! The KLIMOSZ heating boilers are not intended for burning waste and no substances other 

than those recommended by the manufacturer can be burnt in them. 

 

Table 3. Recommended fuel for burning in automatic mode.  

 

Main fuel 

Fuel type 

Granulation [mm] 

Calorific value [MJ/kg] 

Hard coal 

pea grade coal  

Gr II 8 ÷ 20 

(max 30) 

  24 ÷ 28 * 

Substitute 

fuel 

Fuel type 

Granulation [mm] 

Calorific value [MJ/kg] 

Biomass 

pellets ** 

Φ

 6 ÷ 8 

16 ÷ 18 

 

  

*)  

Non-caking, non-coking 

**) 

Sawdust  granulate  (pellets)  should  be  at  least  hard  enough  for  it  to  be  impossible  to  crush 

a  few  fuel  granules  in  a  clenched  fist,  preventing  the  feeder  from  getting  jammed.  Light  colour  grades  are 

recommended, without bark, which can cause deposit formation in the burner. 

 

Table 4. Recommended fuel for burning in manual mode (emergency combustion chamber of the 

 

KLIMOSZ COMBI and KLIMOSZ COMBI B boiler). 

 

Fuel 

Unit 

Size 

non-coking, non-caking hard coal 

Wood 

(mm) 

200 

O I [40 ÷ 80]; Ko II [63 ÷ 125] 

 
 

ATTENTION!!!  MOISTURE  CONTENT  IN  FUEL  MUST  NOT  EXCEED  15%.  USING  MOIST  FUEL 

RESULTS  IN  A  CONSIDERABLE  REDUCTION  IN  THE  BOILER'S  POWER  CAPACITY  (EVEN  BY  AS 

MUCH AS 50%) AND REDUCTION IN THE LIFE-SPAN OF THOSE PARTS OF THE BOILER WHICH ARE 

IN CONTACT WITH MOIST FUEL. USING IMPROPER QUALITY OR MOIST FUEL RESULTS IN LOSING 

WARRANTY RIGHTS WITH RESPECT TO THE PARTS EXPOSED TO CONTACT WITH SUCH FUEL. 

 

 

3.  Construction of the KLIMOSZ COMBI, KLIMOSZ COMBI B boiler 

 

The  KLIMOSZ  COMBI  and  KLIMOSZ  COMBI  B  automatic  boiler  is  not  maintenance-free;  it  is 

therefore  recommended  that  the  user  should  carefully  read  the  principles  of  its  operation,  regulation  and 

maintenance  in  order  to  avoid  any  problems  related  to  its  work.  Construction  of  the  KLIMOSZ  COMBI  boiler 

makes it possible to use solid fuels in the automatic or traditional mode as well as to use liquid fuels. The boiler 

has been constructed on the base of a cast-iron exchanger of the multi-purpose VIADRUS U22 boiler.  The cast-

iron part of the boiler, which is called the upper combustion chamber, can be used for burning coal, coke or wood 

as substitute fuel after manual fuel loading. KLIMOSZ COMBI boilers can be installed in a closed system up to 

working pressure 4,0 bar. 

Under  the  water  grate  of  the  boiler  heat  exchanger  of  a  U22  boiler,  there  is  an  added  steel  combustion 

chamber,  with  (W  version)  or  without  (S  version)  a  water  jacket.  There  are  the  following  cast-iron  parts  in  the 

Summary of Contents for Combi B 15

Page 1: ...Operation and installation manual 2013 03 06 1 o ...

Page 2: ...0 0 6 0 20 0 6 0 20 0 Use of fuel at nominal power continuous heating pea coal 27 5 MJ kg kg h 2 5 3 3 4 1 5 1 pellets 18 MJ kg kg h 3 8 5 1 5 1 4 8 Storage bin volume dm3 230 230 230 230 Approximate combustion time at nominal power pea coal 27MJ kg days 8 5 6 0 5 0 4 0 pellets 16MJ kg days 4 5 3 5 3 5 3 5 Flow of fumes in the smoke conduit pea coal nominal power g s 14 50 15 31 17 68 20 06 Flow o...

Page 3: ... days 3 0 2 5 pellets 16MJ kg days 2 0 1 6 Flow of fumes in the smoke conduit pea coal nominal power g s 24 30 3 Flow of fumes in the smoke conduit pellets nominal power g s 25 28 Recommended working temperature for heating water C 120 260 120 260 Boiler class 3 3 Mass kg 613 630 Heating area of the boiler m2 Water volume dm3 60 65 Diameter of fumes outlet mm 156 156 Chimney draught Pa 15 20 15 20...

Page 4: ...wer g s 11 2 15 31 17 68 18 9 Flow of fumes in the smoke conduit pellets nominal power g s 12 4 16 7 16 7 18 1 Recommended working temperature for heating water C 100 250 100 260 100 260 100 260 Boiler class 3 3 3 Mass kg 460 475 490 525 Heating area of the boiler m2 Water volume dm3 31 40 50 60 Diameter of fumes outlet mm 156 156 156 156 Chimney draught Pa 10 15 10 20 10 20 15 20 Water maximal wo...

Page 5: ...TURE CONTENT IN FUEL MUST NOT EXCEED 15 USING MOIST FUEL RESULTS IN A CONSIDERABLE REDUCTION IN THE BOILER S POWER CAPACITY EVEN BY AS MUCH AS 50 AND REDUCTION IN THE LIFE SPAN OF THOSE PARTS OF THE BOILER WHICH ARE IN CONTACT WITH MOIST FUEL USING IMPROPER QUALITY OR MOIST FUEL RESULTS IN LOSING WARRANTY RIGHTS WITH RESPECT TO THE PARTS EXPOSED TO CONTACT WITH SUCH FUEL 3 Construction of the KLIM...

Page 6: ...me gets to the fuel bin The fan which supplies air for combustion is situated before the fuel bin and is connected to the mixer The amount of air is controlled electronically by the boiler regulator The inlet and outlet of heating water is situated at the back part of the boiler At the back of the boiler there is a smoke conduit which carries flue gas to the chimney The exchanger is insulated with...

Page 7: ...mm 15 1180 795 1555 550 600 630 30 710 1150 1271 250 275 450 275 430 180 20 1180 795 1555 550 600 725 82 710 1150 1271 250 275 630 275 25 1180 795 1555 550 600 725 82 710 1150 1271 250 275 450 275 430 180 32 1180 900 1555 550 600 822 82 710 1150 1271 250 275 450 275 430 180 42 1180 996 1555 600 610 918 95 710 1150 1271 100 100 450 290 50 100 49 1180 1092 1555 600 610 1014 95 710 1150 1271 290 290 ...

Page 8: ...2 L3 H1 H2 Z1 Z2 P1 P2 mm mm mm mm mm mm mm mm mm mm mm mm mm mm 15 1200 655 1410 550 600 470 185 745 1150 1300 95 272 450 275 20 1200 765 1410 550 600 580 185 745 1150 1300 95 272 450 275 32 1200 860 1410 550 600 728 185 745 1150 1300 95 272 450 275 35 1200 950 1410 550 600 813 185 745 1150 1300 95 272 450 275 ...

Page 9: ...ole 4 Storage bin 5 Chamotte plate 6 Upper combustion chamber 7 Inspection hole with the fire grate 8 Cast iron deflector 9 Storage bin cleaning hole 10 Retort burner 11 Measuring hole of feeding pipe 12 Fan 13 Ashpan 14 Boiler feet A B C Combustion chamber mm mm mm dm3 COMBI 15 COMBI B 15 410 230 350 33 COMBI 20 COMBI B 20 410 340 350 48 8 COMBI 25 410 340 350 48 8 COMBI 32 COMBI B 32 410 435 350...

Page 10: ... 6 Retort elbow Fig 5 Schematic diagram of a retort furnace in coal burning 5 1 Delivery and installation KLIMOSZ COMBI B boilers KLIMOSZ COMBI B boilers are supplied in parts on pallet which provides easy transport to the boiler room On the pallet is cast iron VIADRUS U22 boiler 1 Steel base with a retort burner 2 feeding tube 3 motoreducer 6 feeding screw 5 feet 4 fan 7 storage bin 8 controller ...

Page 11: ...BI paraffin fuse 1 item only in KLIMOSZ COMBI Required when biomass is used as fuel protecting valve e g STS Watts instead of the fire fighter required for all boilers 55 75 kW limit switch of the storage bin regulator of boiler emergency extinguishing tank fire fighter for KLIMOSZ COMBI B paraffin fuse 1 item for KLIMOSZ COMBI B room thermostat manual 4 way mixer e g ESBE mixer actuator e g ESBE ...

Page 12: ...completely in the grate and incompletely burnt fuel is removed to the ash pan the heat exchanging area of the heat exchanger gets soiled quicker than usual the flame is short and irregular when the boiler is being heated up fuel burns unevenly in the burner grate NOTE The burner grate should be fixed such that a false draught should not leak out from under it It should be fixed tightly with no pos...

Page 13: ...emove the ceramic catalysts from the retort furnace chamber put the protective plate on the retort burner this prevents lighting the fuel in the retort burner as a result of embers falling down from the upper grate to the ash pan when burning in the upper chamber in the hand firing mode remove fuel from the retort in order to properly supply air for combustion When burning is continued for more th...

Page 14: ...eased resistance to corrosion for example zinc plated The boiler can be cleaned only after it has been extinguished and cooled down Cleaning the walls of the upper combustion chamber can be easily done through the open upper door Cleaning the smoke conduits is done through the inspection hatch under the casing the same as cleaning in automatic mode The boiler can be cleaned with the cleaning tools...

Reviews: