Introductory Remarks 

The purpose of the present Use and Maintenance Manual  is to supply User with directions wi-

thin

 

the range of application, installation, start-up and the operational use of the

 

WPA-BOX-14 fan

 

chamber

 

Installing, start up and operational use are exclusively admissible after getting acquaint- 
ted with the contents of the Use and Maintenance Manual

With regard to continuity of work carried on 

improvement

 of our

 

products, we reserve for oursel- 

ves the revision possibility of the draft  and  technological changes improving  
their functional features and safety. 
 
The construction of the 

WPA-BOX-14 fan

 chamber 

meets the requirements of the current state  

of technology as well as the safety and health assurances included in: 

 

  2006/42/EC

 

Machinery Directive 

of the European Parliament 

and of the Council of

 May 17

th

2006  on machinery 

– amending the 95/16/EC (recast)

 /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

 

 

  2014/35/EC Directive 

of the European Parliament and of the Council of February 26

th

, 2014   

on the harmonisation of the laws of the 

Member States relating to the making 

available

 

on the 

market of electrical equipment designed for use within certain voltage limits. 

/

Journal of Laws EC L96  of 29.03.2014

/

 

 

The appliance meets the requirements included in:

 

 

  2009/125/EC (ErP)

 

Directive 

of the European Parliament and of the Council of October 21

th

2009 

establishing a framework

 for the 

setting of ecodesign requirements

 for energy-related pro-

ducts / 

Journal of Laws L 285 of 31.10.2009

 

 

 

  327/2011

 (

EU

Regulation 

of March 30

th

, 2011 on implementing the 

2009/125/EC Directive

 

 

of the European Parliament and of the Council 

with regard to ecodesign requirements

 for fans 

driven by motors with an electric input power between 125W and 500 kW  / 

Journal of Laws L  

No. 90  of 06.04.2011

 /

 

 
 

The device has been constructed and produced on the basis of following harmonized standards: 

 

 

PN-EN ISO-12100:2012 

 
 

 

“Safety of machinery.  Basic concepts, general principles  

 

 

 

for design.  Risk assessment and risk reduction”. 

 

 

 

 

 

PN-EN 60204-1:2010

 

 
 

 

“Safety of machinery.  – Electrical equipment of machines.  

 

 

 

Part 1:  General requirements”. 

 

 

 

 

 

PN-EN 60034-1:2011E 

 
 

 

“Rotating electrical machines – Part 1: Rating data  

 

 

 

and parameters”. 

 

 

 

 

 

PN-EN ISO 5802:2008E 

 
 

 

“Industrial Fans – Performance testing in situ of installing”. 

 

 

 

 

 

PN-EN ISO 13857:2010 

 

“Safety of machinery.  Safe distances to prevent hazard  

 

 

 

zones being reached by upper and lower limbs”. 

 

 

Summary of Contents for WPA-BOX-14

Page 1: ...1 13 10 2016 Fan chamber WPA BOX 14 Use and Maintenance Manual Fan chamber WPA BOX 14...

Page 2: ...ations of Producer 4 4 Technical Data 4 5 Structure and Function 8 6 Assembly and Start up 10 7 Operational Use 12 8 Troubleshooting Guide 12 9 Maintenance 12 10 Occupational Health and Safety 13 11 T...

Page 3: ...ing to the making available on the market of electrical equipment designed for use within certain voltage limits Journal of Laws EC L96 of 29 03 2014 The appliance meets the requirements included in 2...

Page 4: ...tion with the air create explosive atmosphere F Do not use the device for conveying the air containing viscous impurities that could accumulate build up on the device surface especially on the impelle...

Page 5: ...5 13 10 2016 Fan chamber WPA BOX 14 Fig No 1 Dimensions of the fan chamber WPA BOX 14 Caution The dimension H is pertaining to holes spacing 10 used for anchorage the chamber...

Page 6: ...ensions of the fan chamber Type A mm B mm C mm Connection diameters Pitch diameters of the connections H mm J mm K mm D mm E mm F mm G mm WPA BOX 14 1641 1605 1666 400 400 430 430 766 M8 M8 Flow chart...

Page 7: ...kW see Table No 1 flow efficiency and pressure in the energy efficiency optimisation point see Table No 3 8 Rotations per minute see Table No 1 9 After the period of operational use follow steps acco...

Page 8: ...the floor and it is selec ted according to the weight of the fan stand frame set The fan inlet is equipped with a flange whereas the outlet is secured with a round fitting piece for attachment of the...

Page 9: ...degree Fan chamber with a silencer and air discharge at the silencer outlet Fan chamber with silencers at the inlet and outlet Photo No 1 Examples of application of additional silencers ADDITIONAL EQU...

Page 10: ...l power system has to be executed by User on one s own On the other hand it is important to select the right type and section of the supply cable and choose the appro priate short circuit and overload...

Page 11: ...h Q1 It 1 1 x In where In means rated current of the motor S1 isolating switch It is suggested to install it near the fan Purchase and installing depends on the Investor Connect the motor windings acc...

Page 12: ...tees its efficient function without continuous routing everyday technical supervision Nevertheless to obtain proper function of the device and to follow the safety rules manufacturer suggests executio...

Page 13: ...s this could cause the face injury of User 11 Transport and Storage The fan chamber is transported on a pallet The device has to be firmly fastened to the pallet to protect it from being overturned or...

Page 14: ...L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans dri...

Page 15: ...15 13 10 2016 Fan chamber WPA BOX 14 NOTES...

Page 16: ...amber WPA BOX 14 13 10 2016 Producer KLIMAWENT S A 81 571 Gdynia ul Chwaszczy ska 194 tel 058 629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 814K49 WPA BOX 14 13 10...

Reviews: