4. Technical Data
Table No.1
– Technical data for the subsequent types of fans
Type of the fan Synchronous
rotations
Supply
voltage
Motor
rate
Ingress
pro-
tection
Acoustic
pressure level
[dB(A)]
from distance
Maximum
volume
flow
Maximum
vacuum
Weight
[r.p.m.]
[V]
[kW]
IP
1m
5m
[m
3
/h]
[Pa]
[kg]
WPA-3-P-1-N
3000
230
0,37
54
69
55
1160
940
16
WPA-5-P-1-N
3000
230
0,55
WPA-5-P-3-N
3x400
WPA-6-P-1-N
3000
230
0,75
54
83
69
2500
1700
24
WPA-6-P-3-N
3x400
WPA-7-P-1-N
3000
230
1,1
54
86
72
3100
1800
26
WPA-7-P-3-N
3x400
WPA-8-P-3-N
3000
3x400
1,5
54
88
74
3900
2050
35
WPA-9-P-3-N
3000
3x400
2,2
54
91
77
4500
2400
44
WPA-10-P-3-N
3000
3x400
3,0
54
91
77
6200
2450
55
1.
Maximum temperature of the conveyed air is +
60ºC,
whereas maximum temperature within the work zone +4
0ºC.
2.
Maximum dustiness of the conveyed air should not exceed 0,3 g/m
3
.
Fig. No.1
– Fan of the WPA-P-N series – Structure, dimensions