Klimawent HARD-1000-S Use And Maintenance Manual Download Page 2

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

2 z 8 

Filtering unit

 

HARD-1000-S

 

16.10.2019 

 

 

INTRODUCTION 

The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of 
application, assembly, start-up and operational use of the 

HARD-1000-S

 Filtering unit. 

 

Prior to assembly at the place of operation and use, it is important to get thoroughly acquain-
ted with the contents of the present instruction. 

 

With regard to continuity of work  carried on improvement of our products, we reserve for 
ourselves  the  revision  possibility  of  the  draft  and  technological  changes  improving  their 
functional features and safety.

 

Construction of 

HARD-1000-S

 meets the requirements of the current  state of technology as well as the safety 

and health assurances included in: 
the safety and health assurances included in: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 

2014/35/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the making available on the market of electrical equipment 
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014; 

2009/125/EC (ErP)

 

Directive 

of the European Parliament  and of the Council of 21 October, 2009 establishing 

a framework for the setting  of ecodesign requirements  for energy-related products /  Official Journal  L 285 of 
31.10.2009 / 

327/2011 

(

EC

Regulation 

of 30 March, 2011  on implementing the 

2009/125/EC Directive

 of the European 

Parliament and of the Council  with regard to ecodesign requirements for fans driven by motors with an electric 
input power between 125W and 500 kW / Official Journal L No.90 of 06.04.2011 / 

Is in accordance with the subsequent harmonised standards: 

EN ISO-12100:2012

    

 

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

EN 60204-1:2018-12   

Safety of machinery 

– Electrical equipment of machines  – Part 1:  General requirements 

EN ISO 13857:2010    

Safety of machinery 

– Safe distances to prevent hazard zones from being reached by up-

per and lower limbs 

EN 60529:2003/A2:2014-07

  Degrees of protection provided by enclosures (Code IP) 

EN 61439:2011

   

Low-voltage switchgear and controlgear assemblies 

– Part 1: General resolutions 

 

 

PURPOSE 

HARD-1000-S

 filtering unit is a solution for cleaning the air from viscous dust-gas contamination,  whereby the 

dust can be of viscous and dry properties as well.  It is a perfect solution for subsequent purposes: 

– 

aerosols arising during the spray painting of not large surfaces, 

– 

air contaminated with dust particles and gases arising during laser cutting of rubber, plywood, plexi, acrylic and 
other plastics as well as grinding of the above mentioned materials, 

– 

dust and gas contaminants emitted during polishing of various materials, 

– 

oil-laden welding fumes, accompanied by gases emitted during the welding process, 

– 

air contaminated with grease particles at kitchen extraction hoods, 

– 

unpleasant irritating smells in chemical laboratories, 

– 

vapours arising during upholstery activities, such as cutting, gluing. 

 

 

RESERVATIONS  OF  MANUFACTURER 

 

Manufacturer is not responsible of effects resulting from the operational use that is in contradiction to the 
purpose of application of the device; 

 

Installing of any additional elements that are not belonging to the normal device structure (or accessory 
set) is inadmissible; 

 

Any structural changes / modifications, introduced on one’s own are not allowed; 

 

Protect the device structure from mechanical damage; 

 

Maintenance or any repair should be carried out by an authorised person; 

 

The appliance cannot be used for conveying the air containing viscous and aggressive contaminants as 
these might damage the filters; 

 

During the use take into account that any ignition source 

(

i.e. sparks, cigarette, embers

would be 

drawn into the filtration chamber

.  

 

 

TECHNICAL  DATA 

Table No.1 

Type 

Maximum 

volume flow 

Maximum 

vacuum 

Motor rate 

Supply 

voltage 

Noise level 

[dB(A)]

 

Weight 

 

[m

³/h] 

[Pa] 

[kW] 

[V] 

1m 

5m 

[kg] 

HARD-1000-S 

1250 

1700 

0,75 

230 

70 

67 

180 

CAUTION:  Volume flow has been measured at clean filters;  Filtration efficiency:  9,95% 

Summary of Contents for HARD-1000-S

Page 1: ...ND STARTUP 4 OPERATIONAL USE 5 TROUBLESHOOTING GUIDE 6 MAINTENANCE AND REPAIR 6 OCCUPATIONAL HEALTH AND SAFETY 6 TRANSPORT AND STORAGE 7 TERMS OF WARRANTY 7 DECLARATION OF CONFORMITY 8 16 10 2019 Prod...

Page 2: ...60204 1 2018 12 Safety of machinery Electrical equipment of machines Part 1 General requirements EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from being reached by up...

Page 3: ...ssette with granulated activated carbon weight 20 kg carbon is delivered in bulk two pressure controls pressostats activating the signalling lamp upon excessive flow resistance of the pocket filter an...

Page 4: ...screw out inside the filtering unit the blocking bolts of the activated carbon cassette the wrench is enclo sed to the delivery 4 slide out the cassettes with activated carbon 5 fill out the cassette...

Page 5: ...rs H3 yellow lamp signalizes the replacement necessity of the pocket filter upon limit resistance of the filter 500 Pa the lamp is coordinated with B1 pressure control pressostat H4 yellow lamp indica...

Page 6: ...H1 lamp is on 3 the fan flow capacity decreases high efficiency filter is excessively replace the high efficiency filter whereby the H3 lamp is on polluted 4 unpleasant smell odour is percep activate...

Page 7: ...otected from overturn knocking down and uncontrolled displacement slide Store the device in dry rooms and areas of efficient ventilation TERMS OF WARRANTY The period of warranty for the purchased devi...

Page 8: ...for use within certain voltage limits Official Journal EC L96 of the 29 03 2014 2009 125 EC ErP Directive of the European Parliament and of the Council of 21 October 2009 establishing a framework for...

Reviews: