Klimawent ERGO LUX-D-R Use And Maintenance Manual Download Page 3

 

 3 

 

 

 

 

10.01.2019                                

Standing Extraction Arm

  ERGO LUX-

{

M

;

 

K

;

 

L

;

 

D

}-

R  

 

 

 

1.

 

Introductory Remarks 

 
The purpose of the present 

Use and Maintenance 

Manual

  

is to supply the Purchaser and the  

future User with directions within the range 

of application

, installation, start-up and the opera- 

tional use of the 

ERGO LUX-R  Extraction Arm

 

Therefore, installing, start up and operational use are exclusively admissible after get- 
ting acquainted with the contents of the Use and Maintenance Manual

With regard to continuity of work carried on improvement of our products, we reserve for our-
selves 

the revision possibility

 

of the

 draft and technological changes improving 

their

 functional 

features and safety. 

 

The construction 

of the

 

ERGO LUX-R  Extraction Arm

 

 

meets

 

the requirements of the current

  

state of technology as well as the safety and health assurances included in: 

 

 

2006/42/EC

 

Machinery 

Directive

 

of the European Parliament and of 

the Council

 

of 17 May

2006 on

 

machinery

 

– amending the 95/16/EC (recast)

 /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

 

The device has been constructed and produced on the basis of following harmonized 
standards: 

 

EN ISO-12100:2012 

 
 

 

“Safety of machinery – 

Basic concepts, general

 principles  

 

 

 

for design.  Risk assessment and risk reduction”. 

 

 

2.

 

Application 

ERGO LUX-R  Extraction Arm  has been developed  for capturing the welding dust particles  
and welding gas

  

and also other fine dust particles,

  

directly at the emission source,  in order  

to avoid the

 contamination expanding 

within the

 process room /

  

hall and to 

protect

 the

 people  

in the vicinity from inhaling the contamination.  
The extraction arms

 are 

manufactured in hanging and standing version. They can work inde- 

pendently, in a single configuration

  

with one extraction fan,  or in a group of extraction arms,  

connected to the main collecting ductwork  (with a central fan). 
 
 

 

3.

 

Reservations of Producer 

 

A

.

 

Producer is not responsible for failures  arising during the use that is inconsistent to the 
purpose of application. 

 

 

B

.

 

Installing any additional elements

 not belonging to the 

normal device structure (or acces-

sory set) is not acceptable. 

 

 

C

.

 

Any structural changes

  

or modification of the unit  carried out by User on one’s own are 

not permitted. 

 

 

D

.

 

Protect the

 flexible elements

 and the 

suction duct segment

 (pipe) 

from

 mechanical dama-

ge. 

 

 

E

.

 

Prior to installing examine the load capacity

  

of the of the wall or other building structure  

in points where the device shall be mounted.   
Unsure mounting

  

could cause hazard to personnel / people 

in the vicinity

, as well as da-

mage of the device itself. 

 

 

F

.

  Do not use

 the 

device for conveying

 the

 air mixture with combustible substances, 

in form of gas, vapour, mist or dust 

– that might create explosive atmosphere.  

 

 

Summary of Contents for ERGO LUX-D-R

Page 1: ...1 10 01 2019 Standing Extraction Arm ERGO LUX M K L D R Use and Maintenance Manual Standing Extraction Arm ERGO LUX M R ERGO LUX K R ERGO LUX L R ERGO LUX D R...

Page 2: ...3 3 Reservations of Producer 3 4 Technical Data 4 5 Structure and Function 9 6 Assembly and Start up 9 7 Operational Use 10 8 Troubleshooting Guide 11 9 Maintenance 11 10 Occupational Health and Safe...

Page 3: ...plication ERGO LUX R Extraction Arm has been developed for capturing the welding dust particles and welding gas and also other fine dust particles directly at the emission source in order to avoid the...

Page 4: ...on Arms type ERGO LUX R Dimension weight Remarks Type Dimensions Weight kg Dn mm L m A mm B mm C mm E mm n x F mm G mm hanging version standard hood ERGO LUX M 1 5 R 100 1 8 630 555 335 155 6 x 6 5 23...

Page 5: ...ABS MST 330 100 190 0 35 ERGO LUX M 1 5 R ERGO LUX M 2 R replace able inlet wire mesh KST 330 125 0 36 ERGO LUX K 2 R ERGO LUX K 3 R LST 365 170 0 42 ERGO LUX L 2 R ERGO LUX L 3 R ERGO LUX L 4 R DST...

Page 6: ...l sheet WBN 125 K 250 3 ERGO LUX M R ERGO LUX K R WBN 160 L 320 4 6 ERGO LUX L R WBN 200 D 340 6 1 ERGO LUX D R Fig No 2 Work ranges of the extraction arms Table No 5 Dimensions of the work ranges of...

Page 7: ...7 10 01 2019 Standing Extraction Arm ERGO LUX M K L D R 4 1 Flow charts of the ERGO LUX R extraction arms...

Page 8: ...8 Standing Extraction Arm ERGO LUX M K L D R 10 01 2019 CAUTION The bent position of the arm angle 45 in the middle joint...

Page 9: ...sy manoeuvring with the whole extrac tion arm The suction hood can be equipped with a halogen spot light that can be turned on by means of a switch on the hood The lamp lights up the field of operatio...

Page 10: ...ion arm consists in the settings within the frictional joints The frictional brakes are placed in each joint and their function is to provide the balance and self supporting properties of the whole ex...

Page 11: ...to avoid gluing up the welding chipping on the on the hood surface Undertake the adjustment of its joint system in case when the extraction arm loses its self supporting properties Lubricate the swiv...

Page 12: ...ms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The war ranty does not comprise mechanical damage and dysfunctions caused by User device failures ca...

Page 13: ...and secure it with a hose clamp 5 Screw together the terminations of the gas spring with a plate of the lower joint accor ding to the Fig No 5 Detail A see also Photo No 1 6 Connect the segment II wit...

Page 14: ...14 Standing Extraction Arm ERGO LUX M K L D R 10 01 2019 Fig No 6 Assembly instruction of the extraction arms type ERGO LUX M K L D R Photo No 1 Wall bracket...

Page 15: ...alled at the wall bracket it is important to level the moun ting plane of the wall bracket during its installing to the wall see Photo No 1 If the bracket mounting plane is not horizontal the extracti...

Page 16: ...nd of the Council of May 17th 2006 on machinery amen ding the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The appliance meets following harmonized standard EN ISO 12100 2012 Safety o...

Page 17: ...17 10 01 2019 Standing Extraction Arm ERGO LUX M K L D R NOTES...

Page 18: ...18 Standing Extraction Arm ERGO LUX M K L D R 10 01 2019 NOTES...

Page 19: ...19 10 01 2019 Standing Extraction Arm ERGO LUX M K L D R NOTES...

Page 20: ...K 2 R 10 01 2019 EN 810R83 ERGO LUX K 3 R 10 01 2019 EN 810R84 ERGO LUX L 2 R 10 01 2019 EN 810R85 ERGO LUX L 3 R 10 01 2019 EN 810R86 ERGO LUX L 4 R 10 01 2019 EN 810R87 ERGO LUX D 2 R 10 01 2019 EN...

Reviews: