11
10.01.2019
Extraction Arm
ERGO-FLEX LUX
Assembly instruction of the extraction arms type
– ERGO-FLEX LUX (hanging version)
1.
Take out the extraction arm and the hood from the package and put it stably on an even
surface.
2.
Pull the arm segments apart to enable further assembly.
3.
Put the turnbuckle hook into the eye and screw them together
– see Detail B.
CAUTION:
Screw together the turnbuckle to the moment, when (at the maximum vertical
position), the tensioning mechanism (the spring) would not disconnect.
4.
Adjust the frictional joint
(at the swivel)
in such a way,
that the extraction arm
is easy to ma-
noeuvre and is stable in keeping the requested arm position.
5.
Sleeve the hose onto the swivel and fold up the hose edge inwards and subsequently se-
cure it with a hose clamp.
6.
Adjust the middle joint similarly, as in Clause
4
.
7.
Install the hood at the extraction arm, according to the Detail
A
. Adjust the frictional joint
(of the hood) in such a way, that it is easy to manoeuvre with the hood
and it is keeping
the requested operational position.
8.
Sleeve the other end of the hose, onto the hood. It is important
to fold inwards the hose edge
and secure them with a hose clamp.
9.
Mount the ERGO-FLEX LUX extraction arm on the wall bracket.