RADIAL  ROOF  FANS

  BULLET-N 

 

 
The fan can be restarted after the control steps are carried out, as described in the Section 6  
“Assembly and Start-up” in the present Use and Maintenance Manual. 

Exclusion from this are activities that should be performed at the running fan, and with 
strict observance of the rules of Occupational Health and Safety 

– e.g. measuring of the 

vibrations. 

 

10.

 

Occupational Health and Safety 

Start up and the operational use is only admissible  exclusively after getting acquainted  
with the contents of the present Use and Maintenance Manual

.  The fan will not cause any  

hazard to User / personnel, if it is stably installed  on the roof base or another supporting struc- 
ture of appropriate load carrying capacity. 
Connect the fan to the power supply system, strictly according to the enclosed Connection Dia- 
gram  and  the guidelines  shown in Section 6  of the present 

Use and Maintenance 

Manual.  

This 

ought

 

to be carried out  exclusively

 by a qualified person,

  

and 

in accordance

 with the  

valid regulations / rules of the Occupational Health and Safety

.  During the operational use,  

check the state of the PE protective cable.

 

 

 

 Any technical revisions  and activities connected with repair, have to be 

executed,  necessarily 

after the device disconnection  from the power supply system 

(

isola

ting switch

).

 

 

11.

 

Transport and Storage 

The fans are wrapped with foil and placed in cardboard packages. On the package surface are 
indicated their weights.  During the loading, re-loading and transport,  the packages should not 
be overturned, thrown. Do not put any load on the package.  Stacking of packages is forbidden. 
During the transport it is important to protect the devices  from weather conditions and damage. 
Storage area:  dry rooms and areas of efficient ventilation. 
 

12.

 

Terms of warranty 

The period of warranty for the purchased device is indicated in the “Card of Warranty”. The war- 
ranty does not comprise: 
●  mechanical damage and dysfunctions caused by User, 
● 

device failures caused

 

during

 use which was in contradiction with the purpose of operational 

use and the present Use and Maintenance Manual, 

●  any damages being effected during the improper transport, storage or incorrect maintenance. 

 
Infringement of the Section 3 “Reservations of producer” of the User’s Manual and espe- 

cially modifications

 

undertaken by User on one’s own or operational use that is in contra- 

diction with its purpose shall cause the loss of warranty validity

 

 

Summary of Contents for BULLET-160-N

Page 1: ...3 5 Structure and Function 5 6 Assembly and Start up 6 7 Operational Use 8 8 Trouble Shooting Guide 8 9 Maintenance 8 10 Occupational Health and Safety 9 11 Transport and Storage 9 12 Terms of warran...

Page 2: ...rective of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06...

Page 3: ...ure I During operation the maximum impeller rotations should not exceed the nominal rotations J Producer is not responsible for wounds injuries body laceration experienced by User or per sonnel during...

Page 4: ...4 RADIAL ROOF FANS BULLET N 31 05 2019 Flow chart BULLET 200 N Table No 3 Acoustic pressure level dB A BULLET 200 N outlet inlet 1 m 5 m 10 m 15 m 1 m 63 53 46 43 55 Flow chart BULLET 250 N...

Page 5: ...e introduced under neath the roof bases TPD N or TPDC N 5 Structure and Function A cylindrical ABS plastic housing contains a radial impeller with a motor The housing is protect ted with a plastic hoo...

Page 6: ...cut off the power supply during the servicing Isolating swi tches are in the assortment of KLIMAWENT S A as additional equipment delivery on sepa rate order The switch ought should be installed by Us...

Page 7: ...UTION 1 Overload protection has to be selected by the investor 2 Suggested installing place of the isolating switch near the fan 3 Insulation class I 4 Ingress protection IP44 Fan Motor rate Turbine m...

Page 8: ...Construction provides operational longevity robustness reliable function under the condition of appropriate operational use To obtain correct function of the fan and to observe the principles of Occup...

Page 9: ...the PE protective cable Any technical revisions and activities connected with repair have to be executed necessarily after the device disconnection from the power supply system isola ting switch 11 T...

Page 10: ...ts Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign requir...

Page 11: ...11 31 05 2019 RADIAL ROOF FANS BULLET N NOTES...

Page 12: ...12 RADIAL ROOF FANS BULLET N 31 05 2019 NOTES...

Reviews: