background image

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

23.05.2019

 

Reel Exhaust Extractor

 ALAN-U/C-N

 

5 z 12 

 

 

 

ASSEMBLY  AND  STARTUP 

ALAN-U/C-N-type extractor is being supplied in following assemblies: 

● 

hose reel 

– along with the frame structure (including the spring mechanism and the brake), 

● 

hose assembly 

– lengths 8 or 12 metres;  diameters Ø100, Ø125 or Ø150 mm. The hose assembly consists 

of:  hose, hose clamps, rubber clamp covers for the hose clamps, 

 

● 

rubber stopper, 

● 

nozzle. 

 
 

Additionally, 

extraction fans

 of various types i.e. can be delivered upon separate order: 

 

● 

built-on fans type 

FA

 

– installed directly to the extractor reel; 

● 

flange-type fans 

WPA-E-N

  or  roof fans 

WPA-D-N

 

– mentioned in Section 4; 

 

as well as ventilation conduits (flexible or rigid), wall brackets, roof bases and similar ventilation accessories. 

 

INSTALLING OF THE FAN TYPE FA

The fan has to be installed to the left wall of the framework.  Following steps of installing: 

1

.

 

put a sealing ring on the outlet connection of the reel extractor 

2

.

 

in the bottom part, screw up 2 mounting bolts to fasten the solid bush to the left wall;  put the fan support and 
screw it up with these bolts, along with the solid bush and the framework wall; 

3

.

 

put the fan (with the motor) onto the connection in such a way 

– that the hangers holes (in the upper part of 

the fan) are matching the holes in the left framework wall, and the hole in the support is suitable to the hole in 
the fan housing.  The fan inlet opening ought to be installed evenly  onto the sealing ring. 

4

.

 

screw up the fan with the extractor to the hangers (by means of 4 bolts) and additionally to the support (1 bolt); 
altogether 5 bolts M8x20. 

 

FASTENING  OF  THE  HOSE ASSEMBLY  TO THE REEL

 

1

.

 

Turn by hand the hose reel to the left (when viewing onto the spring housing): 

 

– 

at least 3 rotations for the hose assembly of 8 metres length 

 

– 

at least 4 rotations for the hose assembly of 12 metres length (until the tensioning springs get stretched) 

2

.

 

Protect the hose reel from uncontrolled back reeling  and set it in such a position, as convenient for installing 
the hose assembly. 

3

.

 

Put the hose assembly inside the reel 

– screw up the reducer  to the reducer body  with 2 screws (Fig. No.3). 

4

.

 

Put (sleeve on) the rubber stopper on the hose  and secure it with a hose clamp 

– in a distance of 2 metres 

from free end. 

5

.

 

Install the nozzle at the hose end, fasten it with a hose clamp and secure it with a rubber clamp cover. 

6

.

 

Pull gently the hose to release the reel blockade, so it is easy to turn slowly the reel and the hose assembly is 
winding smoothly onto the reel 

– finally the rubber stopper ends the winding.  

 

 

 

 

Fig. No.3  

–  Hose assembly  –  installing  

 

 

Summary of Contents for ALAN-U/C-12-N

Page 1: ...ION 4 ASSEMBLY AND STARTUP 5 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 9 MAINTENANCE 9 OCCUPATIONAL HEALTH AND SAFETY 9 TRANSPORT AND STORAGE 10 TERMS OF WARRANTY 10 DECLARATION OF CONFORMITY 11 23 05 2...

Page 2: ...t organisation at the workplace i e not being obstacle for a car lift or for high vehicles The appliance works with following fans manufactured by KLIMAWENT S A built on fans FA installed directly at...

Page 3: ...hose assemblies for the ALA U C N reel extractor Type of the hose assembly Hose diameter Weight Hose length Recommended volume flow Flow resistances1 Thermal resistance Application4 Cooperating fans...

Page 4: ...laced the outlet of the extractor to which can be installed a built on radial fan type FA delivery on separate order The outlet of the extractor or of the FA type fan ought to be connected with a rigi...

Page 5: ...motor onto the connection in such a way that the hangers holes in the upper part of the fan are matching the holes in the left framework wall and the hole in the support is suitable to the hole in th...

Page 6: ...teps Fig No 4 Shut off damper with the tensioning line CAUTION the setting of the counting mechanism and the setting of the line tension can be performed after the moment when the spiral spring tensio...

Page 7: ...xhaust Extractor can be installed to the ceiling or by means of brackets to the wall or a supporting column Important is that the reel axis is positioned horizontally For mounting use bolts M12 class...

Page 8: ...mpeller rotation sense ought to be according to the arrow on the fan housing OPERATIONAL USE For safety reasons in order to use the Reel Exhaust Extractor correctly follow subsequent steps 1 Operate t...

Page 9: ...nse noise level and the flow effi ciency is too low MAINTENANCE Any revisions and repair are admissible to be executed by an authorized person Construction of the Reel Exhaust Extractor and of the ext...

Page 10: ...of transport it has to be placed in a way described above in foil and placed in a cardboard package as well as protected from an uncontrolled displacement and overturn During transporting and storage...

Page 11: ...at the product Reel Exhaust Extractor type model ALAN U C N serial number ___________________ year of production ___________________ Meets the requirements of the subsequent European Directives 2006 4...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 12 Reel Exhaust Extractor ALAN U C N 23 05 2019 NOTES...

Reviews: