10
filtering unit
MATRIX-1000-W
17.10.2019
Take out the bag from the device body by gripping at the four handles (in the upper part of the
bag
).
After
the container is
emptied
of the
dust, the cover must be removed and fastened
at
the
device body and additionally secured by hook and loop fasteners.
The
plug should
be stored in
the control chamber.
Frequency of container emptying depends on the intensity of operational
use of the device and
the degree of dustiness / pollution. This should be evaluated during the operation.
8.
Troubleshooting Guide
Table No.2
Problem
Possible reason
Corrective action
1.
The suction efficiency
The net of the hood is dirty
Clean the net or replace
is gradually decreasing
(the net mesh is clogged)
it nor a new
The filter is not penetrable
Clean the filter
– s see Section 7
2.
Sudden vibrations of the Balance loss
Carry out the impeller balancing
fan are occurring
Impeller damage
Replace the impeller
3.
The ERGO extraction
Improperly adjusted frictional Increase the pressure of the
arm is dropping
brake
frictional disc of the brake
by tightening the adjustment nuts
4.
Inefficient filtration
The lower sealing of the filter Check the tightness of the
– smoky air is getting out is not tight to the bottom of sealing, remove the eventual
into the room
the partition of the filtration
pollution between the sealing
chamber
and the bottom
5.
Noise (whistle) of the air Weak clamping force of the
Tighten up the clamp yokes until
right beneath the filter
filter cover onto the upper
the right tightness of the sealing
cover
sealing of the filter.
is obtained.
9.
Maintenance
Every 12 months, check the technical state of the fan, according to the principles of the ope-
rational use of the electrical driving devices.
Replace the cartridge filter every 12
– 24 months, depending on the intensity of the operatio-
nal use.
Maintenance of the ERGO LUX extraction arm consists
in following
steps executed periodically:
●
In case
when the joint system is
losing its self-supporting properties
– undertake its adjus-
tment (according to the rules referring the states of failure of the ERGO LUX extraction
arms).
●
Lubricate periodically the swivel, using solid grease by pressing it into the lubrication nip-
ple placed on the swivel flange).
●
Clean the internal surface of the extraction conduits (of the ERGO LUX extraction arms)
from the deposited pollutants. Frequency of these operations depends on the intensity
of use.
It is recommended to examine the
pollution
state of the
extraction conduits once
for
3
months and to clean them when necessary
.
10.
Occupational Health and Safety
For the safety reasons, connect the device to the power supply according to the being in for-
ce regulations within the range of
personal
protection against
the
electrical shock
and the
short-cir
cuit- and overload effects.
Any connection activities ought to be executed by an authorized qualified person.
Before opening the control unit housing, disconnect
(unplug)
the de-
vice from the power supply system.