Press the Timer button(‘h’ flashes). 

z

Use  the 

  button  to  select  the  time  at  which  the  air  conditioner  must  activate  (between  0  and  10 

hours can be set at every half hour-between 10 and 24 hours can be set at every hour). 

z

Press the Timer button (‘h’ stops flashing) and the preset time appears in the display. 

z

Press the Timer button again to delete the selected data from the memory. 

Note  :  If  no  buttons  are  pressed  during  the  programming  of  the  timer  function,  thee  remote  control  will 

switch off automatically after 10 seconds. 

(2)  To switch the air conditioner off at the desired time, follow the procedure specified below (the remote control 

and air conditioner are switched off): 

z

Press the timer button. 

z

Use the 

 button to select the time at witch. 

13.  EMERGENCY Operation 

When the EMERGENCY Operation switch is pressed once, COOLING mode is selected and if in 3 seconds the 

EMERGENCY Operation switch is pressed again, mode is selected. Then pressed once again, the unit is switch 

off. 

When the remote controller is missing, has failed or the batteries run down, press the EMERGENCY Operation 

switch on the front of the indoor unit. The unit will start. 

The first 30 minutes of operation will be the test run operation. The operation is for servicing. The indoor fan runs 

at high speed and the system is in continuous operation. The thermostat is ON and the timer is reset to normal. 

After 30 minutes of test run operation the system shifts to AUTO COOLING/HEATING mode, and the indoor fan 

runs in automatic speed. The operation continues unit the EMERGENCY operation switch is pressed or a button 

on the remote controller is pressed and normal operation will start. 

NOTE: Do not press the EMERGENCY Operation switch during normal operation. 

14.   AUTO RESTART Function(Option)

1.When the indoor unit is controlled with the remote control, the operation mode, set tem perature, and the fan 

speed  are  memorized  by  the  indoor  electric  control  PCB.  The  AUTO  RESTART  function  sets  to  work  the 

moment power has restored after power failure. Then, the unit will restart automatically. 

2. How to set the AUTO RESTAR function. 

z

Press  the  emergency  switch and  power  supply  to  the  PCB  following,  hold  10 seconds  and  the  buzzer  will 

beep three times. The AUTO-RESTAR is set. 

z

Do the operation again, the buzzer will beep four times and the AUTO-RESTAR function is cancelled. 

15. 

Failure Display and Handling

a) 

Failure Display 

When the controller has failure, the buzzer will sound long for three times, and displays the failure from  the 

failure lamp. 

b) 

Failure Code 

If have the digital pipe that displays the failure code for digital pipe, or display for the run lamp. 

Type of failure 

The lamp flash 

Display of digital pipe 

The failure of room temperature sensor 

Once/cycle 

E1 

The failure of indoor pipe temperature sensor 

Twice/cycle 

E2 

The failure of indoor fan motor 

6 times/cycle 

E6 

c) 

Failure Handling 

z

When the room temperature sensor or the indoor  pipe temperature sensor has a failure, the system will be 

shut off, the compressor will be OFF, and the outdoor fan and the indoor fan will be OFF. The system 

doesn’t  receive  the  signal  of  remoter  controller  except  the  signal  of  shut  off  it.  When  the  failure 

disappear,  the  controller  can  operate  in  normal  mode.  before  this,  presses  the  “ON/OFF”  to  start  the 

system,  and  it  will  operate  in  COOLING  or  HEATING  for  30  minutes,  and  follows  shut  off.  During 

Summary of Contents for KSWT009-C/H113

Page 1: ...ALL MOUNTED SPLIT TYPE AIR CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 Models KSWT009 C H113 SERVICE MANUAL KSWT012 C H113 KSWT018 C H213 KSWT024 C H21...

Page 2: ...appliance may result in personal injury and property damage The manufacturer or seller cannot be responsible for the interpretation of this information nor can it assume any liability in connection w...

Page 3: ...Remote control 6 2 5 3 7 1 Air Conditioner Service Manual Operation Details Remote Control The remote control is not preset as Cooling Only Air Conditioner or Heat Pump by the manufacturer Each time a...

Page 4: ...Air Conditioner Service Manual REMOTE CONTROL GYKQ 05...

Page 5: ......

Page 6: ...2 min More than 2 min More than 2 min More than 2 min Indoor Fan Set Speed Set Speed Set Speed Set Speed Set Speed Compressor ON OFF ON OFF ON Outdoor Fan ON OFF ON OFF ON z During the heating operat...

Page 7: ......

Page 8: ...oor Fan 9 Fan motor control 1 Rotational frequency feedback control The indoor fan motor is equipped with a rotational frequency sensor and outputssignal to the microprocessor to feedback the rotation...

Page 9: ...ositioning is decided as follows z When the ON OFF button is pressed z When the vane control is change from AUTO to MANUAL z When the SWING is finished z When the test run starts z When the power supp...

Page 10: ...pressed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGENCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When...

Page 11: ...nal of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again z When the indoor fan motorfails the co...

Page 12: ...5 594 4972 Fax 305 675 2212 www klimaire com sales klimaire com 2190 NW 89 Place Doral FL 33172 USA The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2010 Klimaire Product...

Reviews: