5
klima-hitze.com
CONNECTION TO THE POWER GRID
1. The electric heater is supplied with connected electric cable which should be connected to
a fixed electric grid, according to the color of the wires.
L - Phase conductor; color-black; N - zero condictor; color-blue; conductor for grounding
color yellow-green.
2. The connection of the water heater to the power grid must be done in accordance with the standards
for electric installations. Between the water heater and the permanent installation there must be built in
a switch which will enable the distance of the contacts in the two poles at an open position to be higher
or equal to 3 mm. This is in accordance with the national regulations for installing. This is a modern type
of water heater with a thermostat which enables you a comfortable use of the product. The thermostat
consists of a regulatory and a protective thermostat.
3. On the control panel, there is a display and you can manually set parameters for working,
and the protective thermostat has a function to protect the whole product from overheating.
The same has a possibility for resetting, if the protection is activated. The handling and setting
of the thermostat can be learned only if you read the instructions in detail and if you act
according to the description given in it.
4. CONTROL PANEL
On the control panel
you can read the following data:
1.1. The water temperature in Celsius degrees (˚C);
1.2 The temperature which is set;
2. Time
2.1. Hour
2.2. Time of postponed heating
3. Mode
3.1. Mistakes
3.2. Mode for postponed heating
3.3. Mode for heating
4. Time of postponed heating
4.1. Time of postponed heating turned on
4.2. Time of postponed heating turned off
5. Heaters
5.1. Heater 1 turned on
5.2. Heater 2 turned on
5. POSSIBILITIES OF THE DEVICE
5.1. By pressing button (SW1), (OFF/ON) which serves for turning on and turning off, a tone
will be heard and the LCD display will be activated. By turning on the display, you will see all
he functions which are described in “CONTROL PANEL” on it.
5.2. The button (SW2)(MENU) serves for moving through the display so that you can change
SW1
SW2
SW3
SW4
88
C
O
88:88
TIMER ON FIRST GEAR
ERR KEEP WARM HEAT