Installation instruction for radial blowers for areas subject to gas and dust explosion hazards
07/2019 KARL KLEIN Ventilatorenbau GmbH
Page 9
GB
2
Designated use
Instruction!
For instance, the blower may be labeled as II2G Ex h IIB T4 Gb
Equipment class II; Category 2; D = Dust; G = Gas; Ex h = non electrical equipment for use
in explosive atmospheres / for conveying explosive atmospheres
IIB = explosion subgroup according CENELEC / IEC / NEC 505
T3 = up to 200 °C surface temperature
T4 = up to 135 °C surface temperature
The blower can be used in atmospheres subject to dust and gas-explosion hazards for
zones 1 and 2, 21 and 22.
In reference to EN 1127-1, this means for Zone 1 that the blower is intended for use in those
areas where an atmosphere capable of producing an explosion, in the form a mixture of
combustible gas, vapor or mist with air, may
occasionally
form under normal operating
conditions.
In reference to EN 1127-1, this means for
Zone 2
that under normal operating conditions, an
atmosphere capable of producing an explosion, in the form a mixture of combustible gas,
vapor or mist with air,
normally does not
form or
only forms for brief periods.
In reference to EN 1127-1, this means for
Zone 21
that the blower is intended for use in
those areas where an atmosphere capable of producing an explosion, in the form of a
combustible dust-cloud mixed with air may
occasionally
form under normal operating
conditions.
In reference to EN 1127-1, this means for
Zone 22
that under normal operating conditions,
an atmosphere capable of producing an explosion, in the form of a combustible dust-cloud
mixed with air,
normally does not
form
or
only forms for brief periods.
The designated use encompasses observing and complying with the specifications and
instructions in this Installation instruction.
2.1
Limitations to the use and special considerations for
designated uses
The designated operation also includes:
The conveyed medium may not contain solid or liquid contaminants. Use a filter as
needed (see KLEIN list of accessories).
When conveying aggressive media, the blower corrosion protection mechanisms must
first be adapted to the material characteristics. (Consult the manufacturer).
If the blower is to be used in an open blowing configuration, or if it is likely that a hazard
exists for the downstream machine or installation if the blower wheel breaks, a
protective screen must be mounted to the blower exhaust opening.
The blower may only be operated in an installed condition, i.e. mounted to or into
systems and machines.
Ventilated air flow at fan inlet with higher or lower values than the specified limits of 0.8
to 1.1 bar for absolute pressure and
–20°C to +60°C for temperature are not permitted,
max. allowed oxygen content is 21 volume percent.
Ambient atmospheres with higher or lower values than the specified limits of 0.8 to 1.1
bar for absolute pressure and
–20°C to +40°C for temperature are not permitted, max.
allowed oxygen content is 21 volume percent.
The blower may only be operated with an installed intake protective screen.