• Use the up and down arrow buttons
to
navigate through the settings.
• Use the left and right arrow buttons to select setting.
• Use the up and down arrow buttons
to change
the selected setting.
• Press the "Enter" button
to accept your changes.
• Press the left arrow to unselect a setting.
changing a setting
• RJ45 VoP : VoP
Set the VoP to be used to measure RJ45 cable.
• Coaxial VoP : VoP
Set the VoP to be used to measure coaxial cable.
• TIA568A/TIA568B: Set the RJ45 wiring configuration to
TIA568A or TIA568B wiring standard.
• Pair/Pin: Set the RJ45 wiremap to measure by pair or pin.
• Meters/Feet :
Set the length measurement to be
displayed in Meters or Feet.
• Pair/Pin can be changed to test the RJ45 from Wire Order to
Pair Order.
• Power Off Timeout:
Set the desired automatic
timeout from 00.5 - 99.9 minutes.
• LCD Dimmer Timeout:
Set the desired automatic
timeout from 00.5 - 99.9 minutes.
• Language: Set the desired language from English (default) to
Spanish or French.
• Tone Generator Timeout: Set the desired automatic timeout
00.5 - 99.9 minutes.
• PoE Test: Turn the PoE test On or Off. Turning the PoE off
will allow the VDV Commander to detect a network without
running a PoE test.
• Press the “Calibrate” function button to calibrate the VDV
Commander. This will calibrate the VDV Commander at 0 ft.
No cables should be connected to the VDV Commander when
performing a calibration.
• Press the "Save"
function button to save your options.
• Note: If only temporary change is desired, do not press the
save button. If the save button is not pressed, the previous
settings will be restored once the unit is powered off.
• To restore factory default values, press the "Defaults"
function button.
• To view saved files, press the Files function button.
ENGLIsH